Update Max discharging and charging battery
This commit is contained in:
parent
6abb0497ae
commit
af38a98e11
|
|
@ -328,10 +328,10 @@ internal static class Program
|
|||
|
||||
if (record.Battery != null)
|
||||
{
|
||||
_oneTimeFlag.WriteLine(" onetime flag");
|
||||
if (record.Battery?.MonomerHighVoltageAlarm == true && !_oneTimeFlag) //this should be checked: the number 0
|
||||
//_oneTimeFlag.WriteLine(" onetime flag");
|
||||
if (record.Battery?.MonomerHighVoltageAlarm == true /*&& !_oneTimeFlag*/) //this should be checked: the number 0
|
||||
{
|
||||
_oneTimeFlag = true;
|
||||
//_oneTimeFlag = true;
|
||||
warningList.Add(new AlarmOrWarning
|
||||
{
|
||||
Date = DateTime.Now.ToString("yyyy-MM-dd"),
|
||||
|
|
@ -340,10 +340,6 @@ internal static class Program
|
|||
Description = "dynCCL Active: Max Battery Charging is 10 * N"
|
||||
});
|
||||
}
|
||||
else
|
||||
{
|
||||
_oneTimeFlag = false;
|
||||
}
|
||||
|
||||
/* if (record.Battery?.MonomerLowVoltageAlarm == true && !_oneTimeFlag) //this should be checked: the number 10
|
||||
{
|
||||
|
|
@ -526,45 +522,52 @@ internal static class Program
|
|||
var configFile = r.Config;
|
||||
var devicesConfig = r.AcDc.Devices.All(d => d.Control.Ac.GridType == GridType.GridTied400V50Hz) ? configFile.GridTie : configFile.IslandMode; // TODO if any of the grid tie mode
|
||||
|
||||
Double maxBatteryChargingCurrentLive ; //used with deligreenBattery for limiting charging
|
||||
Double maxBatteryDischargingCurrentLive; //used with deligreenBattery for limiting discharging
|
||||
Double maxBatteryChargingCurrentLiveByDcDc ; //used with deligreenBattery for limiting charging
|
||||
Double maxBatteryDischargingCurrentLivebyDcDc; //used with deligreenBattery for limiting discharging
|
||||
var dcCount = r.DcDc.Devices.Count;
|
||||
|
||||
r.Battery?.HighestCellVoltage.WriteLine(" HighestCellVoltage");
|
||||
r.Battery?.LowestCellVoltage.WriteLine(" LowestCellVoltage");
|
||||
|
||||
// TODO The discharging current is well calculated but not communicated to live. But Written in S3
|
||||
//r.Battery?.MonomerHighVoltageAlarm.WriteLine(" Monomer High Voltage ");
|
||||
//r.Battery?.MonomerHighVoltageAlarm.WriteLine(" Monomer High Voltage ");
|
||||
|
||||
|
||||
// Deligreen upper current limitation dynCCL
|
||||
if (r.DcDc.Devices.Count != 0 && r.Battery?.MonomerHighVoltageAlarm == true )
|
||||
if (r.Battery != null)
|
||||
{
|
||||
var availableBattries = r.Battery?.AvailableChBatteries;
|
||||
availableBattries?.WriteLine(" Available ChBatteries");
|
||||
r.Battery.HighestCellVoltage.WriteLine(" HighestCellVoltage");
|
||||
r.Battery.LowestCellVoltage.WriteLine(" LowestCellVoltage");
|
||||
|
||||
// Deligreen upper current limitation dynCCL
|
||||
if ( dcCount != 0 && r.Battery.MonomerHighVoltageAlarm )
|
||||
{
|
||||
maxBatteryChargingCurrentLiveByDcDc = 10.0 / dcCount ; // Max charging current is 10 A * Number of batteries
|
||||
Console.WriteLine("dynCCL Active: Max Charging current for one Battery is "+ maxBatteryChargingCurrentLiveByDcDc * dcCount); // multiply by dcCount for display purpose
|
||||
}
|
||||
else
|
||||
{
|
||||
maxBatteryChargingCurrentLiveByDcDc = devicesConfig.DcDc.MaxBatteryChargingCurrent/r.Battery.Devices.Count;
|
||||
}
|
||||
|
||||
// Deligreen lower current limitation dynDCL
|
||||
if ( dcCount != 0 && r.Battery.MonomerLowVoltageAlarm ) // this 10 comparison need to be checked
|
||||
{
|
||||
maxBatteryDischargingCurrentLivebyDcDc = 10.0 / dcCount ; // Max discharging current is 10 A * Number of batteries
|
||||
Console.WriteLine("dynDCL Active: Max disCharging current for one Battery is "+ maxBatteryDischargingCurrentLivebyDcDc * dcCount); // multiply by dcCount for display purpose
|
||||
}
|
||||
else
|
||||
{
|
||||
maxBatteryDischargingCurrentLivebyDcDc = devicesConfig.DcDc.MaxBatteryDischargingCurrent/r.Battery.Devices.Count;
|
||||
}
|
||||
|
||||
maxBatteryChargingCurrentLiveByDcDc *= r.Battery.AvailableChBatteries; // Adapt the current to the number of available battery
|
||||
maxBatteryDischargingCurrentLivebyDcDc *= r.Battery.AvailableDischBatteries; // Adapt the current to the number of available battery
|
||||
|
||||
(r.Battery?.AvailableChBatteries)?.WriteLine(" Available Charging Batteries");
|
||||
(r.Battery?.AvailableDischBatteries)?.WriteLine(" Available Discharging Batteries");
|
||||
|
||||
maxBatteryChargingCurrentLiveByDcDc.WriteLine(" maxBatteryChargingCurrentLive by DcDC");
|
||||
maxBatteryDischargingCurrentLivebyDcDc.WriteLine(" maxBatteryDischargingCurrentLive by DcDc");
|
||||
|
||||
maxBatteryChargingCurrentLive = (10 * availableBattries.Value)/ r.DcDc.Devices.Count ; // Max charging current is 10 A * Number of batteries
|
||||
Console.WriteLine("dynCCL Active: Max Battery Charging is "+ maxBatteryChargingCurrentLive);
|
||||
}
|
||||
else
|
||||
{
|
||||
maxBatteryChargingCurrentLive = devicesConfig.DcDc.MaxBatteryChargingCurrent;
|
||||
maxBatteryChargingCurrentLiveByDcDc = 0;
|
||||
maxBatteryDischargingCurrentLivebyDcDc = 0;
|
||||
}
|
||||
|
||||
// Deligreen lower current limitation dynDCL
|
||||
// if (r.Battery?.Voltage != null && (r.Battery?.LowestCellVoltage ?? 10) < 2.0 ) // this 10 comparison need to be checked
|
||||
// {
|
||||
// maxBatteryDischargingCurrentLive =(r.Battery.Devices.Count * 10)/ r.DcDc.Devices.Count ; // Max discharging current is 10 A * Number of batteries
|
||||
// maxBatteryDischargingCurrentLive.WriteLine("dynDCL Active: Max Battery disCharging is "+ maxBatteryDischargingCurrentLive);
|
||||
// }
|
||||
// else.
|
||||
// {
|
||||
maxBatteryDischargingCurrentLive = devicesConfig.DcDc.MaxBatteryDischargingCurrent;
|
||||
// }
|
||||
|
||||
maxBatteryChargingCurrentLive.WriteLine(" maxBatteryChargingCurrentLive by DcDC");
|
||||
maxBatteryDischargingCurrentLive.WriteLine(" maxBatteryDischargingCurrentLive by DcDc");
|
||||
|
||||
inverters.ForEach(d => d.Control.Dc.MaxVoltage = devicesConfig.AcDc.MaxDcLinkVoltage);
|
||||
inverters.ForEach(d => d.Control.Dc.MinVoltage = devicesConfig.AcDc.MinDcLinkVoltage);
|
||||
inverters.ForEach(d => d.Control.Dc.ReferenceVoltage = devicesConfig.AcDc.ReferenceDcLinkVoltage);
|
||||
|
|
@ -575,8 +578,8 @@ internal static class Program
|
|||
dcDevices.ForEach(d => d.Control.DroopControl.LowerVoltage = devicesConfig.DcDc.LowerDcLinkVoltage);
|
||||
dcDevices.ForEach(d => d.Control.DroopControl.ReferenceVoltage = devicesConfig.DcDc.ReferenceDcLinkVoltage);
|
||||
|
||||
dcDevices.ForEach(d => d.Control.CurrentControl.MaxBatteryChargingCurrent = maxBatteryChargingCurrentLive);
|
||||
dcDevices.ForEach(d => d.Control.CurrentControl.MaxBatteryDischargingCurrent = maxBatteryDischargingCurrentLive);
|
||||
dcDevices.ForEach(d => d.Control.CurrentControl.MaxBatteryChargingCurrent = maxBatteryChargingCurrentLiveByDcDc);
|
||||
dcDevices.ForEach(d => d.Control.CurrentControl.MaxBatteryDischargingCurrent = maxBatteryDischargingCurrentLivebyDcDc);
|
||||
dcDevices.ForEach(d => d.Control.MaxDcPower = devicesConfig.DcDc.MaxDcPower);
|
||||
|
||||
dcDevices.ForEach(d => d.Control.VoltageLimits.MaxBatteryVoltage = devicesConfig.DcDc.MaxChargeBatteryVoltage);
|
||||
|
|
|
|||
Loading…