+ /// Returns an AI-generated diagnosis for a single error/alarm description.
+ /// Responses are cached in memory — repeated calls for the same error code
+ /// do not hit OpenAI again.
+ ///
+ [HttpGet(nameof(DiagnoseError))]
+ public async Task> DiagnoseError(Int64 installationId, string errorDescription, Token authToken)
+ {
+ var user = Db.GetSession(authToken)?.User;
+ if (user == null)
+ return Unauthorized();
+
+ var installation = Db.GetInstallationById(installationId);
+ if (installation is null || !user.HasAccessTo(installation))
+ return Unauthorized();
+
+ // AI diagnostics are scoped to SodistoreHome and SodiStoreMax only
+ if (installation.Product != (int)ProductType.SodioHome &&
+ installation.Product != (int)ProductType.SodiStoreMax)
+ return BadRequest("AI diagnostics not available for this product.");
+
+ if (!DiagnosticService.IsEnabled)
+ return StatusCode(503, "AI diagnostics not configured.");
+
+ var result = await DiagnosticService.DiagnoseAsync(installationId, errorDescription);
+
+ if (result is null)
+ return StatusCode(500, "Diagnosis failed – please try again later.");
+
+ return result;
+ }
+
+ ///
+ /// Test endpoint for AlarmKnowledgeBase - no authentication required.
+ /// Tests multiple Sinexcel and Growatt alarms to verify the knowledge base works.
+ /// Remove this endpoint in production if not needed.
+ ///
+ [HttpGet(nameof(TestAlarmKnowledgeBase))]
+ public ActionResult TestAlarmKnowledgeBase()
+ {
+ var testCases = new[]
+ {
+ // Sinexcel alarms
+ "Fan fault",
+ "Abnormal grid voltage",
+ "Battery 1not connected",
+ "Inverter power tube fault",
+ "Island protection",
+ // Growatt alarms
+ "Warning 300",
+ "Warning 500",
+ "Error 408",
+ "AFCI Fault",
+ // Unknown alarm (should return null - would call OpenAI)
+ "Some unknown alarm XYZ123"
+ };
+
+ var results = new List();
+ foreach (var alarm in testCases)
+ {
+ var diagnosis = AlarmKnowledgeBase.TryGetDiagnosis(alarm);
+ results.Add(new
+ {
+ Alarm = alarm,
+ FoundInKnowledgeBase = diagnosis != null,
+ Explanation = diagnosis?.Explanation ?? "NOT FOUND - Would call OpenAI API",
+ CausesCount = diagnosis?.Causes.Count ?? 0,
+ NextStepsCount = diagnosis?.NextSteps.Count ?? 0
+ });
+ }
+
+ return Ok(new
+ {
+ TestTime = DateTime.Now.ToString("yyyy-MM-dd HH:mm:ss"),
+ TotalTests = testCases.Length,
+ FoundInKnowledgeBase = results.Count(r => ((dynamic)r).FoundInKnowledgeBase),
+ WouldCallOpenAI = results.Count(r => !((dynamic)r).FoundInKnowledgeBase),
+ Results = results
+ });
+ }
+
[HttpPut(nameof(UpdateFolder))]
public ActionResult UpdateFolder([FromBody] Folder folder, Token authToken)
{
diff --git a/csharp/App/Backend/Program.cs b/csharp/App/Backend/Program.cs
index 94f20f312..56208e0f1 100644
--- a/csharp/App/Backend/Program.cs
+++ b/csharp/App/Backend/Program.cs
@@ -2,6 +2,7 @@ using System.Diagnostics;
using Flurl.Http;
using Hellang.Middleware.ProblemDetails;
using InnovEnergy.App.Backend.Database;
+using InnovEnergy.App.Backend.Services;
using InnovEnergy.App.Backend.Websockets;
using InnovEnergy.App.Backend.DeleteOldData;
using Microsoft.AspNetCore.HttpOverrides;
@@ -24,6 +25,7 @@ public static class Program
Watchdog.NotifyReady();
Db.Init();
+ DiagnosticService.Initialize();
var builder = WebApplication.CreateBuilder(args);
RabbitMqManager.InitializeEnvironment();
diff --git a/csharp/App/Backend/Resources/openAiConfig.json b/csharp/App/Backend/Resources/openAiConfig.json
new file mode 100644
index 000000000..43338afc4
--- /dev/null
+++ b/csharp/App/Backend/Resources/openAiConfig.json
@@ -0,0 +1,3 @@
+{
+ "ApiKey": "sk-your-openai-api-key-here"
+}
diff --git a/csharp/App/Backend/Services/AlarmKnowledgeBase.cs b/csharp/App/Backend/Services/AlarmKnowledgeBase.cs
new file mode 100644
index 000000000..09507fc87
--- /dev/null
+++ b/csharp/App/Backend/Services/AlarmKnowledgeBase.cs
@@ -0,0 +1,1514 @@
+using System.Collections.Frozen;
+
+namespace InnovEnergy.App.Backend.Services;
+
+///
+/// Static knowledge base for Sinexcel and Growatt alarms.
+/// Provides pre-defined diagnostics without requiring OpenAI API calls.
+/// Data sourced from vendor alarm documentation.
+///
+public static class AlarmKnowledgeBase
+{
+ ///
+ /// Tries to find a pre-defined diagnostic for the given alarm description.
+ /// Returns null if the alarm is not in the knowledge base.
+ ///
+ public static DiagnosticResponse? TryGetDiagnosis(string alarmDescription)
+ {
+ if (string.IsNullOrWhiteSpace(alarmDescription))
+ return null;
+
+ // Normalize the description for lookup
+ var normalized = alarmDescription.Trim();
+
+ // Try exact match first
+ if (SinexcelAlarms.TryGetValue(normalized, out var sinexcelDiag))
+ return sinexcelDiag;
+
+ if (GrowattAlarms.TryGetValue(normalized, out var growattDiag))
+ return growattDiag;
+
+ // Try case-insensitive match for Sinexcel (alarm names may vary in casing)
+ var lowerDesc = normalized.ToLowerInvariant();
+ foreach (var kvp in SinexcelAlarms)
+ {
+ if (kvp.Key.ToLowerInvariant() == lowerDesc)
+ return kvp.Value;
+ }
+
+ return null;
+ }
+
+ // ── Sinexcel Alarms ──────────────────────────────────────────────────────
+ // Register addresses: 0x1048 - 0x10D5
+ // Recovery types: AUTO (wait), MANUAL (fix and restart), SERVICE (contact service)
+
+ private static readonly FrozenDictionary SinexcelAlarms = new Dictionary
+ {
+ // Grid-related alarms
+ ["Abnormal grid voltage"] = new()
+ {
+ Explanation = "The inverter has detected that the grid voltage is outside the acceptable operating range. This is an ERROR level condition requiring manual intervention.",
+ Causes = new[] { "Utility grid voltage fluctuation", "Poor grid connection", "Local transformer issues", "High load demand on grid" },
+ NextSteps = new[] { "Check the grid voltage with a multimeter", "Verify grid connection wiring", "Fix the underlying cause", "Restart the inverter after the issue is resolved" }
+ },
+ ["Abnormal grid frequency"] = new()
+ {
+ Explanation = "The inverter has detected that the grid frequency is outside the acceptable range (typically 50Hz or 60Hz +/- tolerance). This is an ERROR level condition.",
+ Causes = new[] { "Grid instability", "Generator frequency drift", "Local grid issues" },
+ NextSteps = new[] { "Check grid frequency stability", "If using a generator, verify its frequency setting", "Fix the cause, then restart the inverter" }
+ },
+ ["Inverted sequenceof grid voltage"] = new()
+ {
+ Explanation = "The phase sequence of the three-phase grid voltage is reversed. This is a WARNING level condition.",
+ Causes = new[] { "Incorrect wiring of grid phases (L1, L2, L3)", "Installation error" },
+ NextSteps = new[] { "Power off the system safely", "Swap any two phase wires to correct the sequence", "Restart the inverter" }
+ },
+ ["Grid voltage phase loss"] = new()
+ {
+ Explanation = "One or more phases of the three-phase grid connection are missing. This is an ERROR level condition.",
+ Causes = new[] { "Blown fuse on one phase", "Loose connection on a phase wire", "Grid-side breaker tripped", "Cable damage" },
+ NextSteps = new[] { "Check all three phase connections", "Verify fuses and breakers", "Fix the missing phase connection", "Restart after repair" }
+ },
+ ["Abnormal grid current"] = new()
+ {
+ Explanation = "The grid current is abnormal, which may indicate overcurrent or current imbalance. This is an ERROR level condition.",
+ Causes = new[] { "Grid-side short circuit", "Overloaded system", "Faulty current sensor", "Ground fault" },
+ NextSteps = new[] { "Check for short circuits", "Reduce system load", "Verify current sensor operation", "Fix the cause, then restart" }
+ },
+
+ // Output-related alarms
+ ["Abnormal output voltage"] = new()
+ {
+ Explanation = "The inverter's output voltage is outside acceptable limits. This is an ERROR level condition.",
+ Causes = new[] { "Internal inverter fault", "Overload condition", "Grid voltage influence" },
+ NextSteps = new[] { "Check connected load", "Verify inverter settings", "Fix the cause, then restart the inverter" }
+ },
+ ["Abnormal output frequency"] = new()
+ {
+ Explanation = "The inverter's output frequency is abnormal. This is an ERROR level condition.",
+ Causes = new[] { "Internal control system fault", "Heavy load transients" },
+ NextSteps = new[] { "Reduce load if possible", "Fix the cause, then restart the inverter" }
+ },
+ ["Abnormalnullline"] = new()
+ {
+ Explanation = "The neutral line connection is abnormal. This is an ERROR level condition.",
+ Causes = new[] { "Loose or missing neutral wire", "Neutral wire damage", "Incorrect wiring" },
+ NextSteps = new[] { "Power off safely", "Check neutral wire connection", "Fix wiring issues", "Restart after repair" }
+ },
+ ["Abnormaloff-grid output voltage"] = new()
+ {
+ Explanation = "The off-grid (backup) output voltage is abnormal. This is an ERROR level condition.",
+ Causes = new[] { "Overload on backup output", "Internal inverter issue", "Battery voltage too low" },
+ NextSteps = new[] { "Check backup load", "Verify battery state", "Fix the cause, then restart" }
+ },
+
+ // Temperature alarms
+ ["Excessivelyhigh ambient temperature"] = new()
+ {
+ Explanation = "The ambient temperature around the inverter is too high. This is a WARNING - the inverter may reduce output to protect itself.",
+ Causes = new[] { "Poor ventilation", "High environmental temperature", "Direct sunlight exposure", "Enclosure overheating" },
+ NextSteps = new[] { "Improve ventilation around the inverter", "Provide shade if outdoors", "Consider adding cooling", "Restart after temperature drops" }
+ },
+ ["Excessive radiator temperature"] = new()
+ {
+ Explanation = "The inverter's heat sink/radiator temperature is too high. This is a WARNING level condition.",
+ Causes = new[] { "Blocked air vents", "Fan failure", "High ambient temperature", "Excessive load" },
+ NextSteps = new[] { "Clean air vents and filters", "Check fan operation", "Reduce load temporarily", "Fix the cause, then restart" }
+ },
+ ["PCBover temperature"] = new()
+ {
+ Explanation = "The printed circuit board temperature is too high. This is a WARNING level condition.",
+ Causes = new[] { "Poor cooling", "High ambient temperature", "Excessive power output" },
+ NextSteps = new[] { "Improve ventilation", "Check fan operation", "Allow cooling before restart" }
+ },
+ ["DC converter over temperature"] = new()
+ {
+ Explanation = "The DC converter section is overheating. This is a WARNING level condition.",
+ Causes = new[] { "High charging/discharging current", "Poor cooling", "Ambient temperature too high" },
+ NextSteps = new[] { "Reduce power flow", "Improve ventilation", "Fix the cause, then restart" }
+ },
+ ["Inverter over temperaturealarm"] = new()
+ {
+ Explanation = "The inverter temperature is approaching dangerous levels. This is a WARNING.",
+ Causes = new[] { "Overload", "Poor ventilation", "Fan failure", "High ambient temperature" },
+ NextSteps = new[] { "Reduce load", "Check cooling system", "Fix the cause, then restart" }
+ },
+ ["Inverter over temperature"] = new()
+ {
+ Explanation = "The inverter has overheated. This is a WARNING level condition.",
+ Causes = new[] { "Sustained overload", "Cooling system failure", "Environmental conditions" },
+ NextSteps = new[] { "Allow inverter to cool down", "Check fans and ventilation", "Fix the cause, then restart" }
+ },
+ ["DC converter over temperaturealarm"] = new()
+ {
+ Explanation = "The DC converter temperature alarm is active. This is a WARNING.",
+ Causes = new[] { "High power throughput", "Inadequate cooling" },
+ NextSteps = new[] { "Reduce power flow temporarily", "Check cooling", "Fix the cause, then restart" }
+ },
+
+ // Insulation and safety alarms
+ ["Insulation fault"] = new()
+ {
+ Explanation = "An insulation fault has been detected, indicating possible current leakage to ground. This is an ERROR level safety condition.",
+ Causes = new[] { "Damaged cable insulation", "Moisture ingress", "Component insulation breakdown", "Ground fault in PV array" },
+ NextSteps = new[] { "Do not touch the system", "Power off safely", "Check all cable insulation", "Test insulation resistance", "Repair before restart" }
+ },
+ ["Leakage protection fault"] = new()
+ {
+ Explanation = "The ground fault/leakage current protection has tripped. This is an ERROR level safety condition.",
+ Causes = new[] { "Ground fault in the system", "Damaged insulation", "Moisture in connections", "Faulty RCD/GFCI" },
+ NextSteps = new[] { "Power off the system", "Check for ground faults", "Inspect cable insulation", "Fix the cause before restart" }
+ },
+ ["Abnormal leakage self-check"] = new()
+ {
+ Explanation = "The leakage current self-check has failed. This is an ERROR level condition.",
+ Causes = new[] { "Self-check circuit fault", "Ground fault present", "Sensor malfunction" },
+ NextSteps = new[] { "Power off safely", "Check system grounding", "Fix the cause, then restart" }
+ },
+ ["Poorgrounding"] = new()
+ {
+ Explanation = "Poor grounding connection detected. This is a WARNING level safety condition.",
+ Causes = new[] { "Loose ground connection", "Corroded ground terminal", "High ground resistance", "Missing ground wire" },
+ NextSteps = new[] { "Check all ground connections", "Clean corroded terminals", "Verify ground resistance", "Fix grounding, then restart" }
+ },
+
+ // Fan and cooling alarms
+ ["Fan fault"] = new()
+ {
+ Explanation = "The cooling fan has failed or is not operating correctly. This is an ERROR level condition that can lead to overheating.",
+ Causes = new[] { "Fan motor failure", "Fan blade obstruction", "Loose fan connector", "Control circuit fault" },
+ NextSteps = new[] { "Check fan operation visually", "Remove any obstructions", "Check fan power connection", "Replace fan if faulty" }
+ },
+
+ // Power supply alarms
+ ["Auxiliary power fault"] = new()
+ {
+ Explanation = "The auxiliary power supply inside the inverter has failed. This is an ERROR level condition.",
+ Causes = new[] { "Internal power supply failure", "Input voltage issue", "Component failure" },
+ NextSteps = new[] { "Power cycle the inverter", "If persistent, contact service technician" }
+ },
+
+ // Model and configuration alarms
+ ["Model capacity fault"] = new()
+ {
+ Explanation = "The inverter has detected a model/capacity configuration mismatch. This is an ERROR level condition.",
+ Causes = new[] { "Incorrect model configuration", "Firmware mismatch", "Hardware mismatch" },
+ NextSteps = new[] { "Verify inverter model settings", "Check firmware version", "Fix configuration, then restart" }
+ },
+
+ // Lightning and surge protection
+ ["Abnormal lightning arrester"] = new()
+ {
+ Explanation = "The surge protection device (lightning arrester) has failed or triggered. This is an ERROR level condition.",
+ Causes = new[] { "Lightning strike damage", "Surge event", "SPD component failure" },
+ NextSteps = new[] { "Check SPD indicator", "Replace SPD if triggered", "Fix the cause, then restart" }
+ },
+
+ // Island protection
+ ["Island protection"] = new()
+ {
+ Explanation = "Island protection is active - the inverter has disconnected from the grid to prevent back-feeding during a grid outage. This is an INFO level condition that typically auto-recovers.",
+ Causes = new[] { "Grid power outage", "Grid voltage/frequency outside limits", "Intentional grid disconnection" },
+ NextSteps = new[] { "Wait for grid to stabilize", "The inverter will automatically reconnect when grid is normal", "Monitor until it clears" }
+ },
+
+ // Battery 1 alarms
+ ["Battery 1not connected"] = new()
+ {
+ Explanation = "Battery 1 is not detected or not connected. This is an ERROR level condition.",
+ Causes = new[] { "Battery disconnect switch open", "Loose battery cable", "Battery BMS shutdown", "Battery fuse blown" },
+ NextSteps = new[] { "Check battery disconnect switch", "Verify battery cable connections", "Check battery BMS status", "Fix connection, then restart" }
+ },
+ ["Battery 1over voltage"] = new()
+ {
+ Explanation = "Battery 1 voltage is too high. This is a WARNING level condition - charging will be limited.",
+ Causes = new[] { "Overcharging", "BMS malfunction", "Incorrect battery voltage setting", "Cell imbalance" },
+ NextSteps = new[] { "Check battery SOC", "Verify charging settings", "Check BMS operation", "Fix the cause, then restart" }
+ },
+ ["Battery 1under voltage"] = new()
+ {
+ Explanation = "Battery 1 voltage is too low. This is a WARNING level condition - discharging will be limited.",
+ Causes = new[] { "Battery deeply discharged", "Cell failure", "BMS cutoff", "High load drain" },
+ NextSteps = new[] { "Allow battery to charge", "Check for excessive loads", "Verify battery health", "Fix the cause, then restart" }
+ },
+ ["Battery 1discharge end"] = new()
+ {
+ Explanation = "Battery 1 has reached its discharge end point (minimum SOC). This is an INFO level condition that auto-recovers when charged.",
+ Causes = new[] { "Battery fully discharged to SOC limit", "High power consumption" },
+ NextSteps = new[] { "Wait for battery to recharge from PV or grid", "Monitor until it clears" }
+ },
+ ["Battery 1inverted"] = new()
+ {
+ Explanation = "Battery 1 polarity is reversed. This is a WARNING level condition - do not operate!",
+ Causes = new[] { "Battery cables connected in reverse", "Installation error" },
+ NextSteps = new[] { "IMMEDIATELY power off the system", "Correct battery cable polarity", "Check for damage before restart" }
+ },
+ ["Battery 1over current"] = new()
+ {
+ Explanation = "Battery 1 current exceeds safe limits. This is a WARNING level condition.",
+ Causes = new[] { "Excessive load", "Short circuit", "Inverter control issue" },
+ NextSteps = new[] { "Reduce load", "Check for short circuits", "Fix the cause, then restart" }
+ },
+ ["Battery 1overload timeout"] = new()
+ {
+ Explanation = "Battery 1 has been overloaded for too long. This is an ERROR level condition.",
+ Causes = new[] { "Sustained high load", "Undersized battery", "Battery degradation" },
+ NextSteps = new[] { "Reduce system load", "Check battery capacity", "Fix the cause, then restart" }
+ },
+ ["Battery 1soft start failure"] = new()
+ {
+ Explanation = "Battery 1 failed to soft-start properly. This is a WARNING level condition.",
+ Causes = new[] { "Pre-charge circuit fault", "Battery voltage mismatch", "Contactor issue" },
+ NextSteps = new[] { "Check battery voltage", "Verify pre-charge circuit", "Fix the cause, then restart" }
+ },
+ ["Battery 1power tube fault"] = new()
+ {
+ Explanation = "Battery 1 power electronics (IGBT/MOSFET) have failed. This is a PROTECTION level condition requiring service.",
+ Causes = new[] { "Power semiconductor failure", "Overcurrent damage", "Manufacturing defect" },
+ NextSteps = new[] { "Do not restart the system", "Contact service technician", "Hardware repair required" }
+ },
+ ["Battery 1charging sealingwave"] = new()
+ {
+ Explanation = "Battery 1 charging seal pulse detected. This is a WARNING indicating charging is being limited.",
+ Causes = new[] { "Battery requesting charge termination", "BMS protection active" },
+ NextSteps = new[] { "Check battery BMS status", "Fix the cause, then restart" }
+ },
+ ["Battery 1insufficient power"] = new()
+ {
+ Explanation = "Battery 1 cannot provide sufficient power for the load. This is an INFO level condition.",
+ Causes = new[] { "Low state of charge", "High load demand", "Battery capacity limitation" },
+ NextSteps = new[] { "Wait for battery to recharge", "Reduce load if possible", "Monitor until it clears" }
+ },
+ ["Battery 1backup prohibited"] = new()
+ {
+ Explanation = "Battery 1 is prohibited from providing backup power. This is a WARNING level condition.",
+ Causes = new[] { "BMS protection active", "Battery in maintenance mode", "SOC too low for backup" },
+ NextSteps = new[] { "Check BMS settings", "Verify battery SOC", "Fix the cause, then restart" }
+ },
+
+ // Battery 2 alarms (similar to Battery 1)
+ ["Battery 2not connected"] = new()
+ {
+ Explanation = "Battery 2 is not detected or not connected. This is an ERROR level condition.",
+ Causes = new[] { "Battery disconnect switch open", "Loose battery cable", "Battery BMS shutdown", "Battery fuse blown" },
+ NextSteps = new[] { "Check battery disconnect switch", "Verify battery cable connections", "Check battery BMS status", "Fix connection, then restart" }
+ },
+ ["Battery 2over voltage"] = new()
+ {
+ Explanation = "Battery 2 voltage is too high. This is a WARNING level condition.",
+ Causes = new[] { "Overcharging", "BMS malfunction", "Incorrect voltage setting" },
+ NextSteps = new[] { "Check battery SOC", "Verify charging settings", "Fix the cause, then restart" }
+ },
+ ["Battery 2under voltage"] = new()
+ {
+ Explanation = "Battery 2 voltage is too low. This is a WARNING level condition.",
+ Causes = new[] { "Battery deeply discharged", "Cell failure", "BMS cutoff" },
+ NextSteps = new[] { "Allow battery to charge", "Check battery health", "Fix the cause, then restart" }
+ },
+ ["Battery 2discharge end"] = new()
+ {
+ Explanation = "Battery 2 has reached its discharge end point. This is an INFO level condition.",
+ Causes = new[] { "Battery fully discharged to SOC limit" },
+ NextSteps = new[] { "Wait for battery to recharge", "Monitor until it clears" }
+ },
+ ["Battery 2inverted"] = new()
+ {
+ Explanation = "Battery 2 polarity is reversed. This is a WARNING - do not operate!",
+ Causes = new[] { "Battery cables connected in reverse" },
+ NextSteps = new[] { "IMMEDIATELY power off", "Correct battery polarity", "Check for damage" }
+ },
+ ["Battery 2over current"] = new()
+ {
+ Explanation = "Battery 2 current exceeds safe limits. This is a WARNING level condition.",
+ Causes = new[] { "Excessive load", "Short circuit" },
+ NextSteps = new[] { "Reduce load", "Check for short circuits", "Fix the cause, then restart" }
+ },
+ ["Battery 2overload timeout"] = new()
+ {
+ Explanation = "Battery 2 has been overloaded for too long. This is an ERROR level condition.",
+ Causes = new[] { "Sustained high load", "Battery degradation" },
+ NextSteps = new[] { "Reduce system load", "Fix the cause, then restart" }
+ },
+ ["Battery 2soft start failure"] = new()
+ {
+ Explanation = "Battery 2 failed to soft-start properly. This is a WARNING level condition.",
+ Causes = new[] { "Pre-charge circuit fault", "Voltage mismatch" },
+ NextSteps = new[] { "Check battery voltage", "Fix the cause, then restart" }
+ },
+ ["Battery 2power tube fault"] = new()
+ {
+ Explanation = "Battery 2 power electronics have failed. This is a PROTECTION level condition.",
+ Causes = new[] { "Power semiconductor failure" },
+ NextSteps = new[] { "Do not restart", "Contact service technician" }
+ },
+ ["Battery 2insufficiency power"] = new()
+ {
+ Explanation = "Battery 2 cannot provide sufficient power. This is a WARNING level condition.",
+ Causes = new[] { "Low SOC", "High load demand" },
+ NextSteps = new[] { "Wait for recharge", "Reduce load", "Fix the cause, then restart" }
+ },
+ ["Battery 2charging sealingwave"] = new()
+ {
+ Explanation = "Battery 2 charging seal pulse detected. This is a WARNING.",
+ Causes = new[] { "Battery requesting charge termination" },
+ NextSteps = new[] { "Check BMS status", "Fix the cause, then restart" }
+ },
+ ["Battery 2backup prohibited"] = new()
+ {
+ Explanation = "Battery 2 is prohibited from providing backup power. This is a WARNING.",
+ Causes = new[] { "BMS protection active", "SOC too low" },
+ NextSteps = new[] { "Check BMS settings", "Fix the cause, then restart" }
+ },
+
+ // Lithium battery specific alarms
+ ["Lithium battery 1 chargeforbidden"] = new()
+ {
+ Explanation = "Lithium battery 1 BMS has forbidden charging. This is a WARNING level condition.",
+ Causes = new[] { "Battery fully charged", "Temperature out of range", "BMS protection active", "Cell imbalance" },
+ NextSteps = new[] { "Check battery temperature", "Verify BMS status", "Fix the cause, then restart" }
+ },
+ ["Lithium battery 1 dischargeforbidden"] = new()
+ {
+ Explanation = "Lithium battery 1 BMS has forbidden discharging. This is a WARNING level condition.",
+ Causes = new[] { "Battery empty", "Temperature out of range", "BMS protection", "Low voltage protection" },
+ NextSteps = new[] { "Allow battery to charge", "Check temperature", "Fix the cause, then restart" }
+ },
+ ["Lithium battery 2 chargeforbidden"] = new()
+ {
+ Explanation = "Lithium battery 2 BMS has forbidden charging. This is a WARNING level condition.",
+ Causes = new[] { "Battery fully charged", "Temperature out of range", "BMS protection" },
+ NextSteps = new[] { "Check battery status", "Fix the cause, then restart" }
+ },
+ ["Lithium battery 2 dischargeforbidden"] = new()
+ {
+ Explanation = "Lithium battery 2 BMS has forbidden discharging. This is a WARNING level condition.",
+ Causes = new[] { "Battery empty", "Temperature out of range", "BMS protection" },
+ NextSteps = new[] { "Allow battery to charge", "Fix the cause, then restart" }
+ },
+ ["Lithium battery 1full"] = new()
+ {
+ Explanation = "Lithium battery 1 is fully charged. This is a WARNING indicating charging will stop.",
+ Causes = new[] { "Battery at 100% SOC", "Cell voltage at maximum" },
+ NextSteps = new[] { "Normal condition if intentional", "Monitor battery health" }
+ },
+ ["Lithium battery 1 dischargeend"] = new()
+ {
+ Explanation = "Lithium battery 1 has reached discharge end. This is a WARNING.",
+ Causes = new[] { "Battery at minimum SOC" },
+ NextSteps = new[] { "Allow battery to recharge", "Fix the cause, then restart" }
+ },
+ ["Lithium battery 2full"] = new()
+ {
+ Explanation = "Lithium battery 2 is fully charged. This is a WARNING.",
+ Causes = new[] { "Battery at 100% SOC" },
+ NextSteps = new[] { "Normal condition if intentional" }
+ },
+ ["Lithium battery 2 dischargeend"] = new()
+ {
+ Explanation = "Lithium battery 2 has reached discharge end. This is a WARNING.",
+ Causes = new[] { "Battery at minimum SOC" },
+ NextSteps = new[] { "Allow battery to recharge" }
+ },
+ ["Lead battery temperature abnormality"] = new()
+ {
+ Explanation = "Lead-acid battery temperature is abnormal. This is an ERROR level condition.",
+ Causes = new[] { "Overheating", "Temperature sensor fault", "Environmental temperature extreme" },
+ NextSteps = new[] { "Check battery temperature", "Verify sensor", "Fix the cause, then restart" }
+ },
+ ["Batteryaccessmethod error"] = new()
+ {
+ Explanation = "Battery access method configuration error. This is a WARNING.",
+ Causes = new[] { "Incorrect configuration", "Communication setup error" },
+ NextSteps = new[] { "Check battery configuration", "Fix the cause, then restart" }
+ },
+
+ // PV 1 alarms
+ ["PV 1notaccessed"] = new()
+ {
+ Explanation = "PV string 1 is not detected or accessible. This is a WARNING level condition.",
+ Causes = new[] { "PV disconnector open", "Cable damage", "PV module fault", "No sunlight" },
+ NextSteps = new[] { "Check PV disconnector", "Verify PV cable connections", "Check for shading", "Fix the cause, then restart" }
+ },
+ ["PV 1over voltage"] = new()
+ {
+ Explanation = "PV string 1 voltage exceeds maximum input voltage. This is a WARNING - PV input will be limited.",
+ Causes = new[] { "Too many PV modules in series", "Low temperature increasing voltage", "Design error" },
+ NextSteps = new[] { "Check PV string configuration", "Verify Voc at low temperature", "Reduce modules if needed" }
+ },
+ ["AbnormalPV 1current sharing"] = new()
+ {
+ Explanation = "PV string 1 current sharing is abnormal. This is an ERROR level condition.",
+ Causes = new[] { "Mismatched PV modules", "Partial shading", "Module fault" },
+ NextSteps = new[] { "Check for shading", "Verify module matching", "Fix the cause, then restart" }
+ },
+ ["PV 1power tube fault"] = new()
+ {
+ Explanation = "PV 1 DC converter power electronics have failed. This is a PROTECTION level condition.",
+ Causes = new[] { "IGBT/MOSFET failure", "Overcurrent damage" },
+ NextSteps = new[] { "Do not restart", "Contact service technician" }
+ },
+ ["PV 1soft startfailure"] = new()
+ {
+ Explanation = "PV 1 failed to soft-start properly. This is a WARNING level condition.",
+ Causes = new[] { "Pre-charge circuit fault", "Voltage mismatch" },
+ NextSteps = new[] { "Check PV voltage", "Fix the cause, then restart" }
+ },
+ ["PV 1overload timeout"] = new()
+ {
+ Explanation = "PV 1 has been overloaded for too long. This is an ERROR level condition.",
+ Causes = new[] { "Excessive PV power", "DC converter limitation" },
+ NextSteps = new[] { "Check PV sizing", "Fix the cause, then restart" }
+ },
+ ["PV 1insufficient power"] = new()
+ {
+ Explanation = "PV string 1 is not providing enough power. This is an INFO level condition.",
+ Causes = new[] { "Low irradiance", "Shading", "Cloud cover", "Evening/morning" },
+ NextSteps = new[] { "Wait for better sunlight conditions", "Check for shading", "Monitor until it clears" }
+ },
+ ["Photovoltaic 1 over current"] = new()
+ {
+ Explanation = "PV string 1 current exceeds limits. This is a WARNING level condition.",
+ Causes = new[] { "PV array oversized", "Ground fault", "Short circuit" },
+ NextSteps = new[] { "Check PV configuration", "Look for ground faults", "Fix the cause, then restart" }
+ },
+
+ // PV 2 alarms
+ ["PV 2notaccessed"] = new()
+ {
+ Explanation = "PV string 2 is not detected or accessible. This is a WARNING level condition.",
+ Causes = new[] { "PV disconnector open", "Cable damage", "No sunlight" },
+ NextSteps = new[] { "Check PV disconnector", "Verify connections", "Fix the cause, then restart" }
+ },
+ ["PV 2over voltage"] = new()
+ {
+ Explanation = "PV string 2 voltage exceeds maximum. This is a WARNING level condition.",
+ Causes = new[] { "Too many PV modules in series", "Low temperature" },
+ NextSteps = new[] { "Check PV configuration", "Reduce modules if needed" }
+ },
+ ["AbnormalPV 2current sharing"] = new()
+ {
+ Explanation = "PV string 2 current sharing is abnormal. This is an ERROR level condition.",
+ Causes = new[] { "Mismatched modules", "Partial shading" },
+ NextSteps = new[] { "Check for shading", "Fix the cause, then restart" }
+ },
+ ["PV 2power tube fault"] = new()
+ {
+ Explanation = "PV 2 power electronics have failed. This is a PROTECTION level condition.",
+ Causes = new[] { "Power semiconductor failure" },
+ NextSteps = new[] { "Do not restart", "Contact service technician" }
+ },
+ ["PV 2soft startfailure"] = new()
+ {
+ Explanation = "PV 2 failed to soft-start. This is a WARNING level condition.",
+ Causes = new[] { "Pre-charge fault", "Voltage mismatch" },
+ NextSteps = new[] { "Check PV voltage", "Fix the cause, then restart" }
+ },
+ ["PV 2overload timeout"] = new()
+ {
+ Explanation = "PV 2 has been overloaded for too long. This is an ERROR level condition.",
+ Causes = new[] { "Excessive PV power" },
+ NextSteps = new[] { "Check PV sizing", "Fix the cause, then restart" }
+ },
+ ["PV 2insufficient power"] = new()
+ {
+ Explanation = "PV string 2 is not providing enough power. This is an INFO level condition.",
+ Causes = new[] { "Low irradiance", "Shading" },
+ NextSteps = new[] { "Wait for better conditions", "Monitor until it clears" }
+ },
+ ["Photovoltaic 2 over current"] = new()
+ {
+ Explanation = "PV string 2 current exceeds limits. This is a WARNING level condition.",
+ Causes = new[] { "PV oversized", "Ground fault" },
+ NextSteps = new[] { "Check PV configuration", "Fix the cause, then restart" }
+ },
+
+ // PV 3 alarms
+ ["PV 3not connected"] = new()
+ {
+ Explanation = "PV string 3 is not connected. This is an ERROR level condition.",
+ Causes = new[] { "PV disconnector open", "Cable issue" },
+ NextSteps = new[] { "Check connections", "Fix the cause, then restart" }
+ },
+ ["PV 3over voltage"] = new()
+ {
+ Explanation = "PV string 3 voltage exceeds maximum. This is a WARNING.",
+ Causes = new[] { "Too many modules in series" },
+ NextSteps = new[] { "Check PV configuration" }
+ },
+ ["PV 3average current anomaly"] = new()
+ {
+ Explanation = "PV string 3 current is abnormal. This is a WARNING.",
+ Causes = new[] { "Module mismatch", "Shading" },
+ NextSteps = new[] { "Check modules", "Fix the cause, then restart" }
+ },
+ ["PV 3power tube failure"] = new()
+ {
+ Explanation = "PV 3 power electronics failed. This is a PROTECTION level condition.",
+ Causes = new[] { "Hardware failure" },
+ NextSteps = new[] { "Do not restart", "Contact service" }
+ },
+ ["PV 3soft startfailure"] = new()
+ {
+ Explanation = "PV 3 soft start failed. This is a WARNING.",
+ Causes = new[] { "Pre-charge fault" },
+ NextSteps = new[] { "Fix the cause, then restart" }
+ },
+ ["PV 3overload timeout"] = new()
+ {
+ Explanation = "PV 3 overloaded too long. This is an ERROR.",
+ Causes = new[] { "Excessive power" },
+ NextSteps = new[] { "Fix the cause, then restart" }
+ },
+ ["PV 3reverse connection"] = new()
+ {
+ Explanation = "PV string 3 is connected with reversed polarity. This is a PROTECTION level condition.",
+ Causes = new[] { "Installation error", "Wrong cable connection" },
+ NextSteps = new[] { "Do not restart", "Contact service to correct wiring" }
+ },
+ ["Photovoltaic 3 over current"] = new()
+ {
+ Explanation = "PV string 3 current exceeds limits. This is a WARNING.",
+ Causes = new[] { "PV oversized", "Fault condition" },
+ NextSteps = new[] { "Check configuration", "Fix the cause, then restart" }
+ },
+
+ // PV 4 alarms
+ ["PV 4not connected"] = new()
+ {
+ Explanation = "PV string 4 is not connected. This is an ERROR.",
+ Causes = new[] { "Disconnector open", "Cable issue" },
+ NextSteps = new[] { "Check connections", "Fix the cause, then restart" }
+ },
+ ["PV 4over voltage"] = new()
+ {
+ Explanation = "PV string 4 voltage exceeds maximum. This is a WARNING.",
+ Causes = new[] { "Too many modules" },
+ NextSteps = new[] { "Check configuration" }
+ },
+ ["PV 4average current anomaly"] = new()
+ {
+ Explanation = "PV string 4 current abnormal. This is a WARNING.",
+ Causes = new[] { "Module mismatch" },
+ NextSteps = new[] { "Check modules" }
+ },
+ ["PV 4power tube Failure"] = new()
+ {
+ Explanation = "PV 4 power electronics failed. This is a PROTECTION level condition.",
+ Causes = new[] { "Hardware failure" },
+ NextSteps = new[] { "Do not restart", "Contact service" }
+ },
+ ["PV 4soft startfailure"] = new()
+ {
+ Explanation = "PV 4 soft start failed. This is a WARNING.",
+ Causes = new[] { "Pre-charge fault" },
+ NextSteps = new[] { "Fix the cause, then restart" }
+ },
+ ["PV 4overload timeout"] = new()
+ {
+ Explanation = "PV 4 overloaded too long. This is an ERROR.",
+ Causes = new[] { "Excessive power" },
+ NextSteps = new[] { "Fix the cause, then restart" }
+ },
+ ["PV 4reverse connection"] = new()
+ {
+ Explanation = "PV string 4 polarity reversed. This is a PROTECTION condition.",
+ Causes = new[] { "Wrong wiring" },
+ NextSteps = new[] { "Do not restart", "Contact service" }
+ },
+ ["Photovoltaic 4 over current"] = new()
+ {
+ Explanation = "PV string 4 current exceeds limits. This is a WARNING.",
+ Causes = new[] { "PV oversized" },
+ NextSteps = new[] { "Check configuration" }
+ },
+ ["Insufficient photovoltaic power"] = new()
+ {
+ Explanation = "Not enough PV power available. This is a WARNING.",
+ Causes = new[] { "Low irradiance", "Evening/cloudy" },
+ NextSteps = new[] { "Wait for better conditions", "Fix the cause, then restart" }
+ },
+
+ // DC Bus alarms
+ ["DC busover voltage"] = new()
+ {
+ Explanation = "The DC bus voltage is too high. This is a WARNING level condition.",
+ Causes = new[] { "Excessive charging power", "Regenerative load", "Control fault" },
+ NextSteps = new[] { "Check power balance", "Fix the cause, then restart" }
+ },
+ ["DC busunder voltage"] = new()
+ {
+ Explanation = "The DC bus voltage is too low. This is a WARNING level condition.",
+ Causes = new[] { "Excessive load", "Power supply issue", "Battery depletion" },
+ NextSteps = new[] { "Reduce load", "Check power sources", "Fix the cause, then restart" }
+ },
+ ["DC bus voltage unbalance"] = new()
+ {
+ Explanation = "The DC bus voltage is unbalanced. This is an ERROR level condition.",
+ Causes = new[] { "Capacitor failure", "Control issue", "Asymmetric loading" },
+ NextSteps = new[] { "Check capacitor bank", "Fix the cause, then restart" }
+ },
+ ["Busslow over voltage"] = new()
+ {
+ Explanation = "DC bus slow over-voltage detected. This is a WARNING.",
+ Causes = new[] { "Gradual voltage rise", "Charging imbalance" },
+ NextSteps = new[] { "Check charging control", "Fix the cause, then restart" }
+ },
+ ["Hardware bus over voltage"] = new()
+ {
+ Explanation = "Hardware-level bus over-voltage protection tripped. This is a PROTECTION level condition.",
+ Causes = new[] { "Severe overvoltage event", "Component failure" },
+ NextSteps = new[] { "Do not restart", "Contact service technician" }
+ },
+ ["Bus soft startfailure"] = new()
+ {
+ Explanation = "DC bus failed to soft-start. This is a WARNING.",
+ Causes = new[] { "Pre-charge fault", "Capacitor issue" },
+ NextSteps = new[] { "Check pre-charge circuit", "Fix the cause, then restart" }
+ },
+
+ // Inverter power tube and hardware faults
+ ["Inverter power tube fault"] = new()
+ {
+ Explanation = "The main inverter power electronics (IGBT/MOSFET) have failed. This is a PROTECTION level condition requiring professional service.",
+ Causes = new[] { "Power semiconductor failure", "Overcurrent damage", "Short circuit damage", "Thermal damage" },
+ NextSteps = new[] { "Do not attempt to restart", "Contact service technician", "Hardware repair/replacement required" }
+ },
+ ["Hardware over current"] = new()
+ {
+ Explanation = "Hardware overcurrent protection has tripped. This is a PROTECTION level condition.",
+ Causes = new[] { "Short circuit", "Severe overload", "Component failure" },
+ NextSteps = new[] { "Do not restart", "Contact service technician" }
+ },
+ ["DC converter over voltage"] = new()
+ {
+ Explanation = "DC converter voltage too high. This is a WARNING.",
+ Causes = new[] { "Input overvoltage", "Control issue" },
+ NextSteps = new[] { "Check input voltage", "Fix the cause, then restart" }
+ },
+ ["DC converter hardware over voltage"] = new()
+ {
+ Explanation = "DC converter hardware overvoltage protection. This is a PROTECTION condition.",
+ Causes = new[] { "Severe overvoltage" },
+ NextSteps = new[] { "Do not restart", "Contact service" }
+ },
+ ["DC converter over current"] = new()
+ {
+ Explanation = "DC converter current too high. This is a WARNING.",
+ Causes = new[] { "Overload", "Short circuit" },
+ NextSteps = new[] { "Reduce load", "Fix the cause, then restart" }
+ },
+ ["DC converter hardware over current"] = new()
+ {
+ Explanation = "DC converter hardware overcurrent protection. This is a PROTECTION condition.",
+ Causes = new[] { "Severe overcurrent" },
+ NextSteps = new[] { "Do not restart", "Contact service" }
+ },
+ ["DC converter resonator over current"] = new()
+ {
+ Explanation = "DC converter resonator overcurrent. This is a WARNING.",
+ Causes = new[] { "Resonance condition", "Control issue" },
+ NextSteps = new[] { "Fix the cause, then restart" }
+ },
+
+ // Overload alarms
+ ["System output overload"] = new()
+ {
+ Explanation = "The total system output is overloaded. This is an ERROR level condition.",
+ Causes = new[] { "Too many loads connected", "Load exceeds inverter capacity", "Short circuit in load" },
+ NextSteps = new[] { "Disconnect some loads", "Check for short circuits", "Fix the cause, then restart" }
+ },
+ ["Inverter overload"] = new()
+ {
+ Explanation = "The inverter is overloaded. This is an ERROR level condition.",
+ Causes = new[] { "Load exceeds rated power", "Inrush current from motors", "Short circuit" },
+ NextSteps = new[] { "Reduce connected load", "Check load power rating", "Fix the cause, then restart" }
+ },
+ ["Inverter overload timeout"] = new()
+ {
+ Explanation = "The inverter has been overloaded for too long. This is an ERROR level condition.",
+ Causes = new[] { "Sustained overload condition", "Undersized inverter for load" },
+ NextSteps = new[] { "Permanently reduce load", "Consider larger inverter", "Fix the cause, then restart" }
+ },
+ ["Load power overload"] = new()
+ {
+ Explanation = "Load power exceeds system capacity. This is an ERROR.",
+ Causes = new[] { "Excessive load" },
+ NextSteps = new[] { "Reduce load", "Fix the cause, then restart" }
+ },
+ ["Balancedcircuit overload timeout"] = new()
+ {
+ Explanation = "Balanced circuit overloaded too long. This is an ERROR.",
+ Causes = new[] { "Unbalanced loading", "Phase overload" },
+ NextSteps = new[] { "Balance loads", "Fix the cause, then restart" }
+ },
+
+ // Soft start failures
+ ["Inverter soft start failure"] = new()
+ {
+ Explanation = "The inverter failed during soft-start sequence. This is a WARNING level condition.",
+ Causes = new[] { "Pre-charge resistor fault", "Contactor failure", "DC bus capacitor issue", "Control board fault" },
+ NextSteps = new[] { "Power cycle the system", "Check DC bus voltage", "If persistent, contact service", "Fix the cause, then restart" }
+ },
+
+ // DSP and firmware alarms
+ ["DSP 1para meter setting fault"] = new()
+ {
+ Explanation = "DSP 1 parameter configuration error. This is an ERROR level condition.",
+ Causes = new[] { "Incorrect parameter setting", "Firmware corruption", "Configuration mismatch" },
+ NextSteps = new[] { "Check parameter settings", "Reset to defaults if needed", "Fix the cause, then restart" }
+ },
+ ["DSP 2para meter setting fault"] = new()
+ {
+ Explanation = "DSP 2 parameter configuration error. This is an ERROR level condition.",
+ Causes = new[] { "Incorrect parameter setting", "Firmware corruption" },
+ NextSteps = new[] { "Check parameter settings", "Fix the cause, then restart" }
+ },
+ ["DSPversion compatibility fault"] = new()
+ {
+ Explanation = "DSP firmware version is incompatible. This is an ERROR level condition.",
+ Causes = new[] { "Firmware mismatch between components", "Incomplete firmware update" },
+ NextSteps = new[] { "Update firmware to compatible version", "Contact support if needed" }
+ },
+ ["CPLDversion compatibility fault"] = new()
+ {
+ Explanation = "CPLD version is incompatible. This is an ERROR level condition.",
+ Causes = new[] { "Firmware mismatch", "Incomplete update" },
+ NextSteps = new[] { "Update firmware", "Fix the cause, then restart" }
+ },
+ ["CPLD communication fault"] = new()
+ {
+ Explanation = "Communication with CPLD failed. This is an ERROR level condition.",
+ Causes = new[] { "Internal communication bus fault", "CPLD failure" },
+ NextSteps = new[] { "Power cycle the system", "If persistent, contact service" }
+ },
+ ["DSP communication fault"] = new()
+ {
+ Explanation = "Communication with DSP failed. This is an ERROR level condition.",
+ Causes = new[] { "Internal communication bus fault", "DSP failure" },
+ NextSteps = new[] { "Power cycle the system", "If persistent, contact service" }
+ },
+
+ // Output DC component alarms
+ ["Output voltageDC overlimit"] = new()
+ {
+ Explanation = "DC component in output voltage exceeds limit. This is a WARNING.",
+ Causes = new[] { "Control drift", "Sensor offset", "Hardware issue" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, contact service" }
+ },
+ ["Output currentDC overlimit"] = new()
+ {
+ Explanation = "DC component in output current exceeds limit. This is a WARNING.",
+ Causes = new[] { "Control issue", "Sensor fault" },
+ NextSteps = new[] { "Restart the inverter", "Fix the cause, then restart" }
+ },
+
+ // Relay alarms
+ ["Relayself-checkfails"] = new()
+ {
+ Explanation = "Relay self-check has failed. This is an ERROR level condition.",
+ Causes = new[] { "Relay contact fault", "Relay driver fault", "Welded contacts" },
+ NextSteps = new[] { "Check relay operation", "Fix the cause, then restart" }
+ },
+ ["Inverter relayopen"] = new()
+ {
+ Explanation = "Inverter relay is unexpectedly open. This is an ERROR.",
+ Causes = new[] { "Relay driver fault", "Protection trip" },
+ NextSteps = new[] { "Check protection status", "Fix the cause, then restart" }
+ },
+ ["Inverter relayshort circuit"] = new()
+ {
+ Explanation = "Inverter relay has a short circuit (welded contacts). This is a PROTECTION condition.",
+ Causes = new[] { "Welded relay contacts", "Relay failure" },
+ NextSteps = new[] { "Do not restart", "Contact service to replace relay" }
+ },
+ ["Opencircuitof power grid relay"] = new()
+ {
+ Explanation = "Grid relay is unexpectedly open. This is an ERROR.",
+ Causes = new[] { "Relay fault", "Protection active" },
+ NextSteps = new[] { "Check relay", "Fix the cause, then restart" }
+ },
+ ["Shortcircuitof power grid relay"] = new()
+ {
+ Explanation = "Grid relay has welded contacts. This is an ERROR.",
+ Causes = new[] { "Relay failure" },
+ NextSteps = new[] { "Contact service", "Fix the cause, then restart" }
+ },
+ ["generator Relayopencircuit"] = new()
+ {
+ Explanation = "Generator relay is open. This is an ERROR.",
+ Causes = new[] { "Relay fault" },
+ NextSteps = new[] { "Check relay", "Fix the cause, then restart" }
+ },
+ ["generator Relayshortcircuit"] = new()
+ {
+ Explanation = "Generator relay has welded. This is an ERROR.",
+ Causes = new[] { "Relay failure" },
+ NextSteps = new[] { "Contact service", "Fix the cause, then restart" }
+ },
+
+ // Abnormal inverter
+ ["Abnormal inverter"] = new()
+ {
+ Explanation = "General inverter abnormality detected. This is an ERROR level condition.",
+ Causes = new[] { "Various internal faults", "Control system issue" },
+ NextSteps = new[] { "Power cycle the inverter", "Check for other specific alarms", "Fix the cause, then restart" }
+ },
+
+ // Parallel operation alarms
+ ["Parallel communicationalarm"] = new()
+ {
+ Explanation = "Communication between parallel inverters has failed. This is an ERROR level condition.",
+ Causes = new[] { "Communication cable fault", "Parallel interface failure", "Settings mismatch" },
+ NextSteps = new[] { "Check parallel communication cables", "Verify settings match", "Fix the cause, then restart" }
+ },
+ ["Parallelmodule missing"] = new()
+ {
+ Explanation = "A parallel module is missing from the system. This is a WARNING.",
+ Causes = new[] { "Module offline", "Communication loss", "Power failure on module" },
+ NextSteps = new[] { "Check all parallel modules", "Fix the cause, then restart" }
+ },
+ ["Duplicatemachine numbersforparallel modules"] = new()
+ {
+ Explanation = "Two parallel modules have the same ID number. This is a WARNING.",
+ Causes = new[] { "Configuration error", "Duplicate addressing" },
+ NextSteps = new[] { "Assign unique IDs to each module", "Fix the cause, then restart" }
+ },
+ ["Para meterconflictin parallelmodule"] = new()
+ {
+ Explanation = "Parameter conflict between parallel modules. This is a WARNING.",
+ Causes = new[] { "Mismatched settings between units" },
+ NextSteps = new[] { "Synchronize settings across all units", "Fix the cause, then restart" }
+ },
+
+ // System derating
+ ["Systemderating"] = new()
+ {
+ Explanation = "The system is operating at reduced power (derating). This is a WARNING.",
+ Causes = new[] { "High temperature", "Voltage out of range", "Component limitation" },
+ NextSteps = new[] { "Check temperature and ventilation", "Identify derating cause", "Fix the cause, then restart" }
+ },
+
+ // PV access method
+ ["PVaccessmethod erroralarm"] = new()
+ {
+ Explanation = "PV access configuration error. This is a WARNING.",
+ Causes = new[] { "Incorrect PV configuration", "Wiring mismatch" },
+ NextSteps = new[] { "Check PV configuration settings", "Fix the cause, then restart" }
+ },
+
+ // Reserved alarms
+ ["Reservedalarms 4"] = new()
+ {
+ Explanation = "Reserved alarm 4 is active. This is a WARNING level condition.",
+ Causes = new[] { "Undocumented condition" },
+ NextSteps = new[] { "Monitor the system", "Contact support if issue persists" }
+ },
+ ["Reservedalarms 5"] = new()
+ {
+ Explanation = "Reserved alarm 5 is active. This is a WARNING level condition.",
+ Causes = new[] { "Undocumented condition" },
+ NextSteps = new[] { "Monitor the system", "Contact support if issue persists" }
+ },
+
+ // Meter alarms
+ ["Reverse meter connection"] = new()
+ {
+ Explanation = "The energy meter is connected in reverse. This is a PROTECTION level condition.",
+ Causes = new[] { "Meter CT installed backwards", "Meter wiring reversed" },
+ NextSteps = new[] { "Do not rely on meter readings", "Contact service to correct meter installation" }
+ },
+
+ // Seal pulse
+ ["InverterSealPulse"] = new()
+ {
+ Explanation = "Inverter seal pulse active. This is a WARNING indicating output limiting.",
+ Causes = new[] { "Protection active", "Output limiting" },
+ NextSteps = new[] { "Check system status", "Fix the cause, then restart" }
+ },
+
+ // Diesel generator alarms
+ ["Abnormal diesel generator voltage"] = new()
+ {
+ Explanation = "Diesel generator voltage is abnormal. This is an ERROR.",
+ Causes = new[] { "Generator voltage out of range", "AVR fault" },
+ NextSteps = new[] { "Check generator voltage setting", "Fix the cause, then restart" }
+ },
+ ["Abnormal diesel generator frequency"] = new()
+ {
+ Explanation = "Diesel generator frequency is abnormal. This is an ERROR.",
+ Causes = new[] { "Generator speed issue", "Governor fault" },
+ NextSteps = new[] { "Check generator frequency", "Fix the cause, then restart" }
+ },
+ ["Diesel generator voltage reverse sequence"] = new()
+ {
+ Explanation = "Generator phase sequence is reversed. This is a PROTECTION condition.",
+ Causes = new[] { "Wrong phase wiring" },
+ NextSteps = new[] { "Do not restart", "Contact service to correct wiring" }
+ },
+ ["Diesel generator voltageoutof phase"] = new()
+ {
+ Explanation = "Generator voltage is out of phase with grid. This is an ERROR.",
+ Causes = new[] { "Sync issue", "Phase angle mismatch" },
+ NextSteps = new[] { "Check synchronization", "Fix the cause, then restart" }
+ },
+ ["Generator overload"] = new()
+ {
+ Explanation = "The generator is overloaded. This is an ERROR.",
+ Causes = new[] { "Load exceeds generator capacity" },
+ NextSteps = new[] { "Reduce load", "Fix the cause, then restart" }
+ },
+ }.ToFrozenDictionary();
+
+ // ── Growatt Alarms ───────────────────────────────────────────────────────
+ // Format: "Warning XXX" or "Error XXX" or descriptive text
+
+ private static readonly FrozenDictionary GrowattAlarms = new Dictionary
+ {
+ // Warnings (200-series: PV/String)
+ ["Warning 200"] = new()
+ {
+ Explanation = "String fault detected. One or more PV strings may have issues affecting power generation.",
+ Causes = new[] { "PV panel fault", "String wiring issue", "Connector problem", "Module degradation" },
+ NextSteps = new[] { "Check if PV panels are normal after shutdown", "Inspect string connections", "Look for damaged cables" }
+ },
+ ["Warning 201"] = new()
+ {
+ Explanation = "PV string/PID quick-connect terminals are abnormal.",
+ Causes = new[] { "Loose terminal connections", "Damaged quick-connect", "Corrosion on terminals" },
+ NextSteps = new[] { "Check wiring of string terminals after shutdown", "Clean and secure connections" }
+ },
+ ["Warning 203"] = new()
+ {
+ Explanation = "PV1 or PV2 string is short-circuited.",
+ Causes = new[] { "Cable damage causing short", "Connector failure", "Module junction box fault" },
+ NextSteps = new[] { "Check if PV1 or PV2 is short-circuited", "Inspect cables for damage", "Test string isolation" }
+ },
+ ["Warning 208"] = new()
+ {
+ Explanation = "DC fuse has blown, interrupting PV input.",
+ Causes = new[] { "Overcurrent in DC circuit", "Short circuit", "Fuse fatigue" },
+ NextSteps = new[] { "Power off the system", "Check the fuse", "Identify and fix overcurrent cause before replacing fuse" }
+ },
+ ["Warning 209"] = new()
+ {
+ Explanation = "DC input voltage exceeds the upper threshold - potential damage risk.",
+ Causes = new[] { "Too many PV modules in series", "Cold temperature increasing Voc", "System design error" },
+ NextSteps = new[] { "Turn off DC switch immediately", "Check DC voltage", "Reconfigure string if needed" }
+ },
+ ["Warning 219"] = new()
+ {
+ Explanation = "PID (Potential Induced Degradation) function is abnormal.",
+ Causes = new[] { "PID module fault", "Configuration issue" },
+ NextSteps = new[] { "Restart the inverter", "Check PID settings" }
+ },
+ ["Warning 220"] = new()
+ {
+ Explanation = "A PV string is disconnected.",
+ Causes = new[] { "DC disconnector open", "Cable disconnection", "Connector failure" },
+ NextSteps = new[] { "Check if PV string is properly connected", "Verify DC switches" }
+ },
+ ["Warning 221"] = new()
+ {
+ Explanation = "PV string currents are unbalanced, indicating potential issues.",
+ Causes = new[] { "Shading on some modules", "Module mismatch", "Partial string failure", "Soiling" },
+ NextSteps = new[] { "Check if PV panels of the corresponding string are normal", "Look for shading", "Clean panels" }
+ },
+
+ // Warnings (300-series: Grid/AC)
+ ["Warning 300"] = new()
+ {
+ Explanation = "No utility grid connection detected or grid power failure.",
+ Causes = new[] { "Grid outage", "AC breaker tripped", "Grid cable disconnected", "Utility maintenance" },
+ NextSteps = new[] { "Check if grid is down", "Verify AC breaker status", "Check grid cable connections" }
+ },
+ ["Warning 301"] = new()
+ {
+ Explanation = "Grid voltage is outside the permissible operating range.",
+ Causes = new[] { "Grid voltage too high or too low", "Local grid issues", "Transformer tap setting" },
+ NextSteps = new[] { "Check if grid voltage is within specified range", "Contact utility if persistent" }
+ },
+ ["Warning 302"] = new()
+ {
+ Explanation = "Grid frequency is outside the permissible operating range.",
+ Causes = new[] { "Grid frequency unstable", "Generator frequency drift", "Grid disturbance" },
+ NextSteps = new[] { "Check if grid frequency is within specified range", "Wait for grid to stabilize" }
+ },
+ ["Warning 303"] = new()
+ {
+ Explanation = "The system is experiencing an overload condition.",
+ Causes = new[] { "Connected load exceeds capacity", "Inrush current from appliances", "Short circuit in load" },
+ NextSteps = new[] { "Reduce load connected to EPS output terminal", "Check for faulty appliances" }
+ },
+ ["Warning 308"] = new()
+ {
+ Explanation = "Energy meter communication is lost.",
+ Causes = new[] { "Meter offline", "Communication cable fault", "Meter power loss" },
+ NextSteps = new[] { "Check if meter is properly connected", "Verify communication cable", "Check meter power" }
+ },
+ ["Warning 309"] = new()
+ {
+ Explanation = "Energy meter L and N lines are reversed.",
+ Causes = new[] { "Meter wiring error", "Installation mistake" },
+ NextSteps = new[] { "Check if L line and N line of meter are reversely connected", "Correct wiring" }
+ },
+ ["Warning 310"] = new()
+ {
+ Explanation = "Abnormal voltage detected between neutral (N) and protective earth (PE).",
+ Causes = new[] { "Poor PE connection", "N-PE short somewhere in installation", "Ground fault" },
+ NextSteps = new[] { "Check if PE cable is reliably connected after shutdown", "Verify grounding system" }
+ },
+ ["Warning 311"] = new()
+ {
+ Explanation = "Phase sequence error detected. The system will auto-adjust.",
+ Causes = new[] { "Three-phase wiring in wrong order" },
+ NextSteps = new[] { "No operation required", "The PCS will automatically adjust phase sequence" }
+ },
+
+ // Warnings (400-series: System/Internal)
+ ["Warning 400"] = new()
+ {
+ Explanation = "Cooling fan failure detected - risk of overheating.",
+ Causes = new[] { "Fan motor failure", "Fan blocked", "Fan connector loose", "Fan control fault" },
+ NextSteps = new[] { "Check if fan is properly connected after shutdown", "Remove obstructions", "Replace fan if faulty" }
+ },
+ ["Warning 401"] = new()
+ {
+ Explanation = "Energy meter is reporting abnormal readings.",
+ Causes = new[] { "Meter malfunction", "Configuration error", "Communication issue" },
+ NextSteps = new[] { "Check if meter is turned on", "Verify meter configuration" }
+ },
+ ["Warning 402"] = new()
+ {
+ Explanation = "Communication with PV optimizer is abnormal.",
+ Causes = new[] { "Optimizer offline", "Communication interference", "Optimizer fault" },
+ NextSteps = new[] { "Check if optimizer is turned on", "Verify communication wiring" }
+ },
+ ["Warning 407"] = new()
+ {
+ Explanation = "System temperature is too high - power may be limited.",
+ Causes = new[] { "Poor ventilation", "High ambient temperature", "Fan failure", "Excessive load" },
+ NextSteps = new[] { "Restart the inverter", "If fault persists, improve cooling", "Contact manufacturer if unresolved" }
+ },
+ ["Warning 408"] = new()
+ {
+ Explanation = "NTC temperature sensor is broken or disconnected.",
+ Causes = new[] { "Sensor failure", "Sensor cable damaged", "Connector issue" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, sensor may need replacement" }
+ },
+ ["Warning 411"] = new()
+ {
+ Explanation = "Synchronization signal is abnormal (for parallel systems).",
+ Causes = new[] { "Sync cable fault", "Sync interface failure", "Configuration mismatch" },
+ NextSteps = new[] { "Check if sync cable is abnormal", "Verify connections" }
+ },
+ ["Warning 412"] = new()
+ {
+ Explanation = "Grid-connection startup requirements are not met.",
+ Causes = new[] { "Grid voltage/frequency out of range", "Incorrect startup voltage configuration" },
+ NextSteps = new[] { "Check if grid voltage is within specified range", "Check grid-connection startup voltage configuration" }
+ },
+
+ // Warnings (500-series: Battery)
+ ["Warning 500"] = new()
+ {
+ Explanation = "Inverter cannot communicate with the battery BMS.",
+ Causes = new[] { "BMS offline", "Communication cable fault", "Protocol mismatch", "Battery in sleep mode" },
+ NextSteps = new[] { "Check if battery is turned on", "Verify RS485 communication cable", "Wake up battery if in sleep mode" }
+ },
+ ["Warning 501"] = new()
+ {
+ Explanation = "Battery is disconnected from the system.",
+ Causes = new[] { "Battery breaker off", "Cable disconnected", "BMS shutdown", "Battery fault" },
+ NextSteps = new[] { "Check if battery is properly connected", "Verify battery breaker", "Check BMS status" }
+ },
+ ["Warning 502"] = new()
+ {
+ Explanation = "Battery voltage is too high.",
+ Causes = new[] { "Overcharging", "BMS fault", "Cell imbalance", "Voltage setting error" },
+ NextSteps = new[] { "Check if battery voltage is within permissible range", "Verify charging settings" }
+ },
+ ["Warning 503"] = new()
+ {
+ Explanation = "Battery voltage is too low.",
+ Causes = new[] { "Battery deeply discharged", "Cell failure", "High load drain", "BMS cutoff" },
+ NextSteps = new[] { "Check if battery voltage is within permissible range", "Allow battery to charge" }
+ },
+ ["Warning 504"] = new()
+ {
+ Explanation = "Battery positive and negative terminals are reversed.",
+ Causes = new[] { "Installation error", "Wrong cable connection" },
+ NextSteps = new[] { "Check if positive and negative terminals of battery are reversely connected", "CORRECT IMMEDIATELY - risk of damage" }
+ },
+ ["Warning 505"] = new()
+ {
+ Explanation = "Lead-acid battery temperature sensor is disconnected.",
+ Causes = new[] { "Sensor not installed", "Sensor cable fault", "Sensor failure" },
+ NextSteps = new[] { "Check if temperature sensor of lead-acid battery is installed", "Verify connections" }
+ },
+ ["Warning 506"] = new()
+ {
+ Explanation = "Battery temperature is outside the safe operating range.",
+ Causes = new[] { "High ambient temperature", "Poor battery ventilation", "Battery overheating", "Cold environment" },
+ NextSteps = new[] { "Check if ambient temperature of battery is within specified range", "Improve battery cooling/heating" }
+ },
+ ["Warning 507"] = new()
+ {
+ Explanation = "Battery BMS has reported a fault preventing charging and discharging.",
+ Causes = new[] { "BMS internal fault", "Cell protection triggered", "Communication error" },
+ NextSteps = new[] { "Figure out the cause according to BMS error code", "Check battery status display" }
+ },
+ ["Warning 508"] = new()
+ {
+ Explanation = "Lithium battery overload protection has activated.",
+ Causes = new[] { "Load power exceeds battery discharge rating", "High inrush current" },
+ NextSteps = new[] { "Check if power of load exceeds BAT rated discharge power", "Reduce load" }
+ },
+ ["Warning 509"] = new()
+ {
+ Explanation = "BMS communication is abnormal.",
+ Causes = new[] { "Communication timeout", "Protocol error", "Cable fault" },
+ NextSteps = new[] { "Restart the inverter", "Check BMS communication cable" }
+ },
+ ["Warning 510"] = new()
+ {
+ Explanation = "Battery surge protection device (SPD) function is abnormal.",
+ Causes = new[] { "SPD triggered", "SPD failure", "Lightning damage" },
+ NextSteps = new[] { "Check BAT SPD after powering off device", "Replace SPD if triggered" }
+ },
+
+ // Warnings (600-series: Off-grid/EPS)
+ ["Warning 600"] = new()
+ {
+ Explanation = "Output DC component bias is abnormal.",
+ Causes = new[] { "Sensor drift", "Control issue", "Hardware fault" },
+ NextSteps = new[] { "Restart the inverter", "If fault persists, contact manufacturer" }
+ },
+ ["Warning 601"] = new()
+ {
+ Explanation = "DC component in output voltage is too high.",
+ Causes = new[] { "Control drift", "Sensor fault", "Transformer issue" },
+ NextSteps = new[] { "Restart the inverter", "Check output for DC offset" }
+ },
+ ["Warning 602"] = new()
+ {
+ Explanation = "Off-grid/EPS output voltage is too low.",
+ Causes = new[] { "Overload", "Battery voltage low", "Inverter limitation" },
+ NextSteps = new[] { "Restart the inverter", "Reduce load", "If fault persists, contact manufacturer" }
+ },
+ ["Warning 603"] = new()
+ {
+ Explanation = "Off-grid/EPS output voltage is too high.",
+ Causes = new[] { "Control fault", "Voltage regulation issue" },
+ NextSteps = new[] { "Restart the inverter", "If fault persists, contact manufacturer" }
+ },
+ ["Warning 604"] = new()
+ {
+ Explanation = "Off-grid output current overcurrent detected.",
+ Causes = new[] { "Load exceeds specification", "Short circuit in load", "Inrush current" },
+ NextSteps = new[] { "Check if load is within specification", "Look for short circuits" }
+ },
+ ["Warning 605"] = new()
+ {
+ Explanation = "Off-grid DC bus voltage is too low.",
+ Causes = new[] { "Battery depleted", "High load demand", "Power electronics issue" },
+ NextSteps = new[] { "Check if load power exceeds upper limit", "Allow battery to charge" }
+ },
+ ["Warning 606"] = new()
+ {
+ Explanation = "Off-grid output is overloaded.",
+ Causes = new[] { "Load exceeds EPS capacity", "Too many appliances on backup" },
+ NextSteps = new[] { "Check if load is within specification", "Reduce backup load" }
+ },
+ ["Warning 609"] = new()
+ {
+ Explanation = "Phase balancing circuit is abnormal.",
+ Causes = new[] { "Balance circuit fault", "Control issue" },
+ NextSteps = new[] { "Restart the inverter", "Check phase balance" }
+ },
+
+ // Errors (Protection-level faults)
+ ["Error 309"] = new()
+ {
+ Explanation = "Grid Rate of Change of Frequency (ROCOF) is abnormal - anti-islanding protection.",
+ Causes = new[] { "Grid instability", "Generator operation nearby", "Grid fault" },
+ NextSteps = new[] { "Check grid frequency", "Restart the inverter", "Wait for grid to stabilize" }
+ },
+ ["Error 311"] = new()
+ {
+ Explanation = "Export limitation fail-safe has triggered.",
+ Causes = new[] { "CT disconnected", "Meter communication lost", "Feedback loop failure" },
+ NextSteps = new[] { "After shutdown, check connection of CT and meter", "Verify export limit settings" }
+ },
+ ["Error 400"] = new()
+ {
+ Explanation = "DCI (DC Injection) bias is abnormal - safety protection.",
+ Causes = new[] { "DC injection into grid", "Sensor fault", "Transformer issue" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 402"] = new()
+ {
+ Explanation = "High DC component detected in output current.",
+ Causes = new[] { "Output filter issue", "Control fault", "Transformer saturation" },
+ NextSteps = new[] { "Restart the inverter", "Check output connections" }
+ },
+ ["Error 404"] = new()
+ {
+ Explanation = "DC bus voltage sampling is abnormal.",
+ Causes = new[] { "Voltage sensor fault", "ADC error", "Hardware issue" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 405"] = new()
+ {
+ Explanation = "Internal relay fault detected.",
+ Causes = new[] { "Relay failure", "Contact welding", "Driver circuit fault" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, relay replacement needed" }
+ },
+ ["Error 408"] = new()
+ {
+ Explanation = "System over-temperature - shutdown for protection.",
+ Causes = new[] { "Cooling failure", "High ambient temperature", "Blocked ventilation", "Overload" },
+ NextSteps = new[] { "After shutdown, check temperature", "Restart after temperature is within acceptable range" }
+ },
+ ["Error 409"] = new()
+ {
+ Explanation = "DC bus voltage is abnormal.",
+ Causes = new[] { "Power electronics fault", "Capacitor issue", "Control failure" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 411"] = new()
+ {
+ Explanation = "Internal communication failure between control boards.",
+ Causes = new[] { "Communication board fault", "Cable loose", "EMI interference" },
+ NextSteps = new[] { "Check wiring of communication board after shutdown", "Restart inverter" }
+ },
+ ["Error 412"] = new()
+ {
+ Explanation = "Temperature sensor is disconnected.",
+ Causes = new[] { "Sensor failure", "Cable fault", "Connector issue" },
+ NextSteps = new[] { "Check wiring of communication board after shutdown", "Replace sensor if faulty" }
+ },
+ ["Error 413"] = new()
+ {
+ Explanation = "IGBT gate drive fault detected.",
+ Causes = new[] { "Driver circuit failure", "IGBT fault", "Power supply issue" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires professional service" }
+ },
+ ["Error 414"] = new()
+ {
+ Explanation = "EEPROM read/write error.",
+ Causes = new[] { "Memory chip fault", "Data corruption", "Hardware failure" },
+ NextSteps = new[] { "Restart the inverter", "Factory reset may be required" }
+ },
+ ["Error 415"] = new()
+ {
+ Explanation = "Auxiliary power supply is abnormal.",
+ Causes = new[] { "Internal power supply failure", "Component fault" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 416"] = new()
+ {
+ Explanation = "DC/AC overcurrent protection has triggered.",
+ Causes = new[] { "Short circuit", "Severe overload", "Power electronics fault" },
+ NextSteps = new[] { "Restart the inverter", "Check for short circuits", "Reduce load" }
+ },
+ ["Error 417"] = new()
+ {
+ Explanation = "Communication protocol mismatch between components.",
+ Causes = new[] { "Firmware version mismatch", "Configuration error" },
+ NextSteps = new[] { "Restart the inverter", "Update firmware if needed" }
+ },
+ ["Error 418"] = new()
+ {
+ Explanation = "DSP and COM board firmware versions are mismatched.",
+ Causes = new[] { "Incomplete firmware update", "Wrong firmware loaded" },
+ NextSteps = new[] { "Restart the inverter", "Perform complete firmware update" }
+ },
+ ["Error 419"] = new()
+ {
+ Explanation = "DSP software and hardware versions are mismatched.",
+ Causes = new[] { "Hardware replacement with incompatible firmware" },
+ NextSteps = new[] { "Restart the inverter", "Contact support for firmware update" }
+ },
+ ["Error 421"] = new()
+ {
+ Explanation = "CPLD (programmable logic) is abnormal.",
+ Causes = new[] { "CPLD failure", "Firmware corruption" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 422"] = new()
+ {
+ Explanation = "Redundancy sampling values are inconsistent.",
+ Causes = new[] { "Sensor mismatch", "Calibration error", "Hardware fault" },
+ NextSteps = new[] { "Restart the inverter", "May require recalibration" }
+ },
+ ["Error 423"] = new()
+ {
+ Explanation = "PWM pass-through signal failure.",
+ Causes = new[] { "Control board fault", "Signal path issue" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 425"] = new()
+ {
+ Explanation = "AFCI (Arc Fault Circuit Interrupter) self-test failed.",
+ Causes = new[] { "AFCI module fault", "Self-test circuit issue" },
+ NextSteps = new[] { "Restart the inverter", "AFCI may need replacement" }
+ },
+ ["Error 426"] = new()
+ {
+ Explanation = "PV current sampling is abnormal.",
+ Causes = new[] { "Current sensor fault", "ADC error" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 427"] = new()
+ {
+ Explanation = "AC current sampling is abnormal.",
+ Causes = new[] { "CT fault", "Sensor failure", "ADC error" },
+ NextSteps = new[] { "Restart the inverter", "Check CT connections" }
+ },
+ ["Error 429"] = new()
+ {
+ Explanation = "DC bus soft-boot (pre-charge) failed.",
+ Causes = new[] { "Pre-charge circuit fault", "Capacitor issue", "Relay fault" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, requires service" }
+ },
+ ["Error 430"] = new()
+ {
+ Explanation = "EPO (Emergency Power Off) fault triggered.",
+ Causes = new[] { "EPO button pressed", "EPO circuit activated", "Safety system trigger" },
+ NextSteps = new[] { "Restart the inverter", "Check EPO circuit if unintentional" }
+ },
+ ["Error 431"] = new()
+ {
+ Explanation = "Monitoring chip BOOT verification failed.",
+ Causes = new[] { "Firmware corruption", "Chip failure" },
+ NextSteps = new[] { "Restart the inverter", "May require firmware reload" }
+ },
+
+ // Battery Errors
+ ["Error 500"] = new()
+ {
+ Explanation = "BMS failed to communicate with the inverter.",
+ Causes = new[] { "RS485 cable fault", "BMS offline", "Protocol mismatch" },
+ NextSteps = new[] { "Check connection of RS485 cable between inverter and battery" }
+ },
+ ["Error 501"] = new()
+ {
+ Explanation = "BMS reports that battery cannot charge or discharge.",
+ Causes = new[] { "BMS internal fault", "Protection triggered", "Cell issue" },
+ NextSteps = new[] { "Figure out the fault based on BMS error code", "Check battery status" }
+ },
+ ["Error 503"] = new()
+ {
+ Explanation = "Battery voltage exceeds upper threshold.",
+ Causes = new[] { "Overcharging", "BMS fault", "Cell failure" },
+ NextSteps = new[] { "Check battery voltage", "If within permissible range, restart inverter" }
+ },
+ ["Error 504"] = new()
+ {
+ Explanation = "Battery temperature is outside safe charging/discharging range.",
+ Causes = new[] { "Battery too hot", "Battery too cold", "Sensor fault" },
+ NextSteps = new[] { "Check temperature of the battery", "Improve battery environment" }
+ },
+ ["Error 506"] = new()
+ {
+ Explanation = "Battery is open-circuited (not connected).",
+ Causes = new[] { "Battery cable disconnected", "Fuse blown", "BMS cutoff" },
+ NextSteps = new[] { "Check wiring of battery terminals", "Verify fuses" }
+ },
+ ["Error 507"] = new()
+ {
+ Explanation = "Battery overload protection has triggered.",
+ Causes = new[] { "Load exceeds battery discharge rating" },
+ NextSteps = new[] { "Check if power of load exceeds battery rated discharge power", "Reduce load" }
+ },
+ ["Error 508"] = new()
+ {
+ Explanation = "Secondary DC bus voltage is abnormal.",
+ Causes = new[] { "Power electronics fault", "Control issue" },
+ NextSteps = new[] { "Restart the inverter" }
+ },
+ ["Error 509"] = new()
+ {
+ Explanation = "Battery charge overcurrent protection (OCP) triggered.",
+ Causes = new[] { "PV oversized for battery", "Charge current setting too high" },
+ NextSteps = new[] { "Check if PV voltage is oversized", "Reduce charge current setting" }
+ },
+ ["Error 510"] = new()
+ {
+ Explanation = "Battery discharge overcurrent protection (OCP) triggered.",
+ Causes = new[] { "Load too high", "Discharge current setting wrong" },
+ NextSteps = new[] { "Check if battery discharge current configuration is proper", "Reduce load" }
+ },
+ ["Error 511"] = new()
+ {
+ Explanation = "Battery soft-start failed.",
+ Causes = new[] { "Pre-charge circuit fault", "Battery voltage mismatch" },
+ NextSteps = new[] { "Restart the inverter", "Check battery voltage" }
+ },
+
+ // Off-grid Errors
+ ["Error 601"] = new()
+ {
+ Explanation = "Off-grid DC bus voltage is too low.",
+ Causes = new[] { "Battery depleted", "High load", "Power electronics issue" },
+ NextSteps = new[] { "Check if battery is working properly or has capacity loss" }
+ },
+ ["Error 602"] = new()
+ {
+ Explanation = "Abnormal voltage detected at off-grid terminal.",
+ Causes = new[] { "External voltage present", "Wiring fault", "Backfeed" },
+ NextSteps = new[] { "Check if a voltage is present at AC port", "Verify wiring" }
+ },
+ ["Error 603"] = new()
+ {
+ Explanation = "Off-grid soft-start failed.",
+ Causes = new[] { "Pre-charge failure", "Load too heavy at startup" },
+ NextSteps = new[] { "Restart the inverter", "Reduce initial load" }
+ },
+ ["Error 604"] = new()
+ {
+ Explanation = "Off-grid output voltage is abnormal.",
+ Causes = new[] { "Control fault", "Hardware issue" },
+ NextSteps = new[] { "Restart the inverter" }
+ },
+ ["Error 605"] = new()
+ {
+ Explanation = "Balanced circuit self-test failed.",
+ Causes = new[] { "Balance circuit fault" },
+ NextSteps = new[] { "Restart the inverter" }
+ },
+ ["Error 606"] = new()
+ {
+ Explanation = "High DC component in output voltage.",
+ Causes = new[] { "Control drift", "Transformer issue" },
+ NextSteps = new[] { "Restart the inverter" }
+ },
+ ["Error 608"] = new()
+ {
+ Explanation = "Off-grid parallel communication signal is abnormal.",
+ Causes = new[] { "Parallel cable fault", "Configuration mismatch" },
+ NextSteps = new[] { "Check if communication cables are properly connected" }
+ },
+
+ // Special fault codes
+ ["AFCI Fault"] = new()
+ {
+ Explanation = "An arc fault has been detected in the PV system - fire risk protection activated.",
+ Causes = new[] { "Loose connection causing arcing", "Damaged cable insulation", "Connector fault", "Module junction box issue" },
+ NextSteps = new[] { "After shutdown, check connection of PV string", "Inspect all connectors", "Look for damaged insulation" }
+ },
+ ["GFCI High"] = new()
+ {
+ Explanation = "Excessively high ground fault/leakage current detected.",
+ Causes = new[] { "Ground fault in PV array", "Insulation breakdown", "Moisture ingress", "Cable damage" },
+ NextSteps = new[] { "Restart the inverter", "If persistent, check PV array insulation" }
+ },
+ ["PV Voltage High"] = new()
+ {
+ Explanation = "DC input voltage exceeds the maximum safe limit.",
+ Causes = new[] { "Too many PV modules in series", "Cold temperature increasing Voc" },
+ NextSteps = new[] { "Disconnect DC switch immediately", "Check voltage", "Reconfigure strings if needed" }
+ },
+ }.ToFrozenDictionary();
+}
diff --git a/csharp/App/Backend/Services/DiagnosticService.cs b/csharp/App/Backend/Services/DiagnosticService.cs
new file mode 100644
index 000000000..ef9f0b22e
--- /dev/null
+++ b/csharp/App/Backend/Services/DiagnosticService.cs
@@ -0,0 +1,188 @@
+using System.Collections.Concurrent;
+using Flurl.Http;
+using InnovEnergy.App.Backend.Database;
+using InnovEnergy.App.Backend.DataTypes;
+using Newtonsoft.Json;
+
+namespace InnovEnergy.App.Backend.Services;
+
+///
+/// Calls OpenAI to generate plain-English diagnostics for errors/warnings.
+/// Caches responses in-memory keyed by error description so the same
+/// error code is only sent to the API once.
+///
+public static class DiagnosticService
+{
+ private static string _apiKey = "";
+
+ /// In-memory cache: errorDescription → parsed response.
+ private static readonly ConcurrentDictionary Cache = new();
+
+ // ── initialisation ──────────────────────────────────────────────
+
+ public static void Initialize()
+ {
+ var configPath = Path.Combine(AppDomain.CurrentDomain.BaseDirectory, "Resources", "openAiConfig.json");
+
+ if (!File.Exists(configPath))
+ {
+ // Fallback: look relative to the working directory (useful in dev)
+ configPath = Path.Combine("Resources", "openAiConfig.json");
+ }
+
+ if (!File.Exists(configPath))
+ {
+ Console.Error.WriteLine("[DiagnosticService] openAiConfig.json not found – AI diagnostics disabled.");
+ return;
+ }
+
+ var json = File.ReadAllText(configPath);
+ var config = JsonConvert.DeserializeObject(json);
+
+ if (config is null || string.IsNullOrWhiteSpace(config.ApiKey))
+ {
+ Console.Error.WriteLine("[DiagnosticService] ApiKey is empty – AI diagnostics disabled.");
+ return;
+ }
+
+ _apiKey = config.ApiKey;
+ Console.WriteLine("[DiagnosticService] initialised.");
+ }
+
+ public static bool IsEnabled => !string.IsNullOrEmpty(_apiKey);
+
+ // ── public entry-point ──────────────────────────────────────────
+
+ ///
+ /// Returns a diagnosis for .
+ /// First checks the static AlarmKnowledgeBase for known Sinexcel/Growatt alarms.
+ /// Falls back to in-memory cache, then calls OpenAI only for unknown alarms.
+ ///
+ public static async Task DiagnoseAsync(Int64 installationId, string errorDescription)
+ {
+ // 1. Check the static knowledge base first (no API call needed)
+ var knownDiagnosis = AlarmKnowledgeBase.TryGetDiagnosis(errorDescription);
+ if (knownDiagnosis is not null)
+ {
+ Console.WriteLine($"[DiagnosticService] Found diagnosis in knowledge base for: {errorDescription}");
+ return knownDiagnosis;
+ }
+
+ // 2. If AI is not enabled, we can't proceed further
+ if (!IsEnabled) return null;
+
+ // 3. Check in-memory cache for previously fetched AI diagnoses
+ if (Cache.TryGetValue(errorDescription, out var cached))
+ return cached;
+
+ // 4. Gather context from the DB for AI prompt
+ var installation = Db.GetInstallationById(installationId);
+ if (installation is null) return null;
+
+ var productName = ((ProductType)installation.Product).ToString();
+
+ var recentDescriptions = Db.Errors
+ .Where(e => e.InstallationId == installationId)
+ .OrderByDescending(e => e.Date + " " + e.Time) // Date/Time stored as strings in DB
+ .Select(e => e.Description)
+ .Distinct() // deduplicate — same error repeated adds no signal
+ .Take(5)
+ .ToList();
+
+ // 5. Build prompt and call OpenAI API (only for unknown alarms)
+ Console.WriteLine($"[DiagnosticService] Calling OpenAI for unknown alarm: {errorDescription}");
+ var prompt = BuildPrompt(errorDescription, productName, recentDescriptions);
+ var response = await CallOpenAiAsync(prompt);
+
+ if (response is null) return null;
+
+ // 6. Store in cache for future requests
+ Cache.TryAdd(errorDescription, response);
+ return response;
+ }
+
+ // ── prompt ──────────────────────────────────────────────────────
+
+ private static string BuildPrompt(string errorDescription, string productName, List recentErrors)
+ {
+ var recentList = recentErrors.Count > 0
+ ? string.Join(", ", recentErrors)
+ : "none";
+
+ return $@"You are a technician for Innovenergy {productName} battery energy storage systems.
+These are lithium-ion BESS units with a BMS, PV inverter, and grid inverter.
+
+Error: {errorDescription}
+Other recent errors: {recentList}
+
+Explain in plain English for a homeowner. List likely causes and next steps.
+Reply with ONLY valid JSON, no markdown:
+{{""explanation"":""2-3 sentences"",""causes"":[""...""],""nextSteps"":[""...""]}}
+";
+ }
+
+ // ── OpenAI HTTP call ────────────────────────────────────────────
+
+ private static readonly string OpenAiUrl = "https://api.openai.com/v1/chat/completions";
+
+ private static async Task CallOpenAiAsync(string userPrompt)
+ {
+ try
+ {
+ var requestBody = new
+ {
+ model = "gpt-4o-mini", // cost-efficient, fast; swap to "gpt-4" if quality needs tuning
+ messages = new[]
+ {
+ new { role = "user", content = userPrompt }
+ },
+ max_tokens = 400,
+ temperature = 0.2 // low temperature for factual consistency
+ };
+
+ var responseText = await OpenAiUrl
+ .SetHeader("Authorization", $"Bearer {_apiKey}")
+ .SetHeader("Content-Type", "application/json")
+ .PostJsonAsync(requestBody)
+ .ReceiveString();
+
+ // parse OpenAI envelope
+ var envelope = JsonConvert.DeserializeObject(responseText);
+ var content = (string?) envelope?.choices?[0]?.message?.content;
+
+ if (string.IsNullOrWhiteSpace(content))
+ {
+ Console.Error.WriteLine("[DiagnosticService] OpenAI returned empty content.");
+ return null;
+ }
+
+ // parse the JSON the model produced
+ var diagnostic = JsonConvert.DeserializeObject(content);
+ return diagnostic;
+ }
+ catch (FlurlHttpException httpEx)
+ {
+ Console.Error.WriteLine($"[DiagnosticService] HTTP error {httpEx.Response?.StatusCode}: {await httpEx.Response?.GetStringAsync()}");
+ return null;
+ }
+ catch (Exception ex)
+ {
+ Console.Error.WriteLine($"[DiagnosticService] {ex.Message}");
+ return null;
+ }
+ }
+}
+
+// ── config / response models ────────────────────────────────────────────────
+
+public class OpenAiConfig
+{
+ public string ApiKey { get; set; } = "";
+}
+
+public class DiagnosticResponse
+{
+ public string Explanation { get; set; } = "";
+ public IReadOnlyList Causes { get; set; } = Array.Empty();
+ public IReadOnlyList NextSteps { get; set; } = Array.Empty();
+}
diff --git a/typescript/frontend-marios2/src/content/dashboards/Log/Log.tsx b/typescript/frontend-marios2/src/content/dashboards/Log/Log.tsx
index 9ef2ffa7e..a6ac90f1a 100644
--- a/typescript/frontend-marios2/src/content/dashboards/Log/Log.tsx
+++ b/typescript/frontend-marios2/src/content/dashboards/Log/Log.tsx
@@ -1,7 +1,9 @@
import React, { useContext, useEffect, useState } from 'react';
import {
Alert,
+ Box,
Card,
+ CircularProgress,
Container,
Divider,
Grid,
@@ -17,7 +19,7 @@ import { AxiosError, AxiosResponse } from 'axios/index';
import routes from '../../../Resources/routes.json';
import { useNavigate } from 'react-router-dom';
import { TokenContext } from '../../../contexts/tokenContext';
-import { ErrorMessage } from '../../../interfaces/S3Types';
+import { ErrorMessage, DiagnosticResponse } from '../../../interfaces/S3Types';
import Button from '@mui/material/Button';
import FormControlLabel from '@mui/material/FormControlLabel';
import Checkbox from '@mui/material/Checkbox';
@@ -45,6 +47,11 @@ function Log(props: LogProps) {
const tokencontext = useContext(TokenContext);
const { removeToken } = tokencontext;
+ const [diagnosis, setDiagnosis] = useState(null);
+ const [diagnosisLoading, setDiagnosisLoading] = useState(false);
+ const [diagnosisExpanded, setDiagnosisExpanded] = useState(false);
+ const [diagnosedError, setDiagnosedError] = useState('');
+
useEffect(() => {
axiosConfig
.get(`/GetAllErrorsForInstallation?id=${props.id}`)
@@ -71,6 +78,34 @@ function Log(props: LogProps) {
});
}, [updateCount]);
+ // fetch AI diagnosis for the first unseen error (or warning if no unseen errors)
+ useEffect(() => {
+ const target = errors.find(e => !e.seen) || warnings.find(w => !w.seen);
+
+ if (!target) {
+ setDiagnosis(null);
+ setDiagnosedError('');
+ return;
+ }
+
+ // already have a diagnosis for this exact description — skip
+ if (target.description === diagnosedError && diagnosis) return;
+
+ setDiagnosisLoading(true);
+ axiosConfig
+ .get(`/DiagnoseError?installationId=${props.id}&errorDescription=${encodeURIComponent(target.description)}`)
+ .then((res: AxiosResponse) => {
+ setDiagnosis(res.data);
+ setDiagnosedError(target.description);
+ })
+ .catch(() => {
+ setDiagnosis(null);
+ })
+ .finally(() => {
+ setDiagnosisLoading(false);
+ });
+ }, [errors, warnings]);
+
const handleErrorButtonPressed = () => {
setErrorButtonPressed(!errorButtonPressed);
};
@@ -108,6 +143,7 @@ function Log(props: LogProps) {
};
const warningDescriptionMap: { [key: string]: string } = {
+ // BMS warnings
"TaM1": "TaM1: BMS temperature high",
"TbM1": "TbM1: Battery temperature high",
"VBm1": "VBm1: Bus voltage low",
@@ -124,10 +160,131 @@ function Log(props: LogProps) {
"MPMM": "MPMM: Midpoint wiring problem",
"TCdi": "TCdi: Temperature difference between strings high",
"LMPW": "LMPW: String voltages unbalance warning",
- "TOCW": "TOCW: Top of Charge requested"
+ "TOCW": "TOCW: Top of Charge requested",
+
+ // Sinexcel warnings (WARNING/INFO severity)
+ "Inverted sequenceof grid voltage": "Grid phase sequence reversed",
+ "Excessivelyhigh ambient temperature": "Ambient temperature too high",
+ "Excessive radiator temperature": "Radiator/heatsink temperature high",
+ "Island protection": "Island protection active (auto-recovers)",
+ "Battery 1over voltage": "Battery 1 voltage too high",
+ "Battery 1under voltage": "Battery 1 voltage too low",
+ "Battery 1discharge end": "Battery 1 discharge complete (auto-recovers)",
+ "Battery 1inverted": "Battery 1 polarity reversed!",
+ "Battery 2over voltage": "Battery 2 voltage too high",
+ "Battery 2under voltage": "Battery 2 voltage too low",
+ "Battery 2discharge end": "Battery 2 discharge complete (auto-recovers)",
+ "Battery 2inverted": "Battery 2 polarity reversed!",
+ "PV 1notaccessed": "PV string 1 not accessible",
+ "PV 1over voltage": "PV string 1 voltage too high",
+ "PV 2notaccessed": "PV string 2 not accessible",
+ "PV 2over voltage": "PV string 2 voltage too high",
+ "DC busover voltage": "DC bus voltage too high",
+ "DC busunder voltage": "DC bus voltage too low",
+ "Inverter soft start failure": "Inverter soft-start failed",
+ "Battery 1soft start failure": "Battery 1 soft-start failed",
+ "Battery 2soft start failure": "Battery 2 soft-start failed",
+ "Output voltageDC overlimit": "DC component in output voltage high",
+ "Output currentDC overlimit": "DC component in output current high",
+ "Poorgrounding": "Poor ground connection detected",
+ "PV 1soft startfailure": "PV 1 soft-start failed",
+ "PV 2soft startfailure": "PV 2 soft-start failed",
+ "PCBover temperature": "PCB temperature too high",
+ "DC converter over temperature": "DC converter temperature high",
+ "Busslow over voltage": "Slow bus over-voltage",
+ "DC converter over voltage": "DC converter voltage high",
+ "DC converter over current": "DC converter current high",
+ "DC converter resonator over current": "DC converter resonator overcurrent",
+ "PV 1insufficient power": "PV 1 power insufficient (auto-recovers)",
+ "PV 2insufficient power": "PV 2 power insufficient (auto-recovers)",
+ "Battery 1insufficient power": "Battery 1 power insufficient (auto-recovers)",
+ "Battery 2insufficiency power": "Battery 2 power insufficient",
+ "Lithium battery 1 chargeforbidden": "Lithium battery 1 charging forbidden",
+ "Lithium battery 1 dischargeforbidden": "Lithium battery 1 discharging forbidden",
+ "Lithium battery 2 chargeforbidden": "Lithium battery 2 charging forbidden",
+ "Lithium battery 2 dischargeforbidden": "Lithium battery 2 discharging forbidden",
+ "Lithium battery 1full": "Lithium battery 1 fully charged",
+ "Lithium battery 1 dischargeend": "Lithium battery 1 discharge end",
+ "Lithium battery 2full": "Lithium battery 2 fully charged",
+ "Lithium battery 2 dischargeend": "Lithium battery 2 discharge end",
+ "Inverter over temperaturealarm": "Inverter over-temperature alarm",
+ "Inverter over temperature": "Inverter temperature high",
+ "DC converter over temperaturealarm": "DC converter over-temperature alarm",
+ "Systemderating": "System power derating active",
+ "PVaccessmethod erroralarm": "PV access method error",
+ "Parallelmodule missing": "Parallel module missing",
+ "Duplicatemachine numbersforparallel modules": "Duplicate parallel module IDs",
+ "Para meterconflictin parallelmodule": "Parameter conflict in parallel modules",
+ "Reservedalarms 4": "Reserved alarm 4",
+ "InverterSealPulse": "Inverter seal pulse active",
+ "PV 3over voltage": "PV 3 voltage too high",
+ "PV 3average current anomaly": "PV 3 current anomaly",
+ "PV 4over voltage": "PV 4 voltage too high",
+ "PV 4average current anomaly": "PV 4 current anomaly",
+ "PV 3soft startfailure": "PV 3 soft-start failed",
+ "PV 4soft startfailure": "PV 4 soft-start failed",
+ "Batteryaccessmethod error": "Battery access method error",
+ "Reservedalarms 5": "Reserved alarm 5",
+ "Battery 1backup prohibited": "Battery 1 backup prohibited",
+ "Battery 2backup prohibited": "Battery 2 backup prohibited",
+ "Bus soft startfailure": "Bus soft-start failed",
+ "Insufficient photovoltaic power": "Insufficient PV power",
+ "Photovoltaic 1 over current": "PV 1 overcurrent",
+ "Photovoltaic 2 over current": "PV 2 overcurrent",
+ "Photovoltaic 3 over current": "PV 3 overcurrent",
+ "Photovoltaic 4 over current": "PV 4 overcurrent",
+ "Battery 1over current": "Battery 1 overcurrent",
+ "Battery 2over current": "Battery 2 overcurrent",
+ "Battery 1charging sealingwave": "Battery 1 charge limiting",
+ "Battery 2charging sealingwave": "Battery 2 charge limiting",
+
+ // Growatt warnings
+ "Warning 200": "String fault",
+ "Warning 201": "PV string/PID terminals abnormal",
+ "Warning 203": "PV1 or PV2 short circuited",
+ "Warning 208": "DC fuse blown",
+ "Warning 209": "DC input voltage too high",
+ "Warning 219": "PID function abnormal",
+ "Warning 220": "PV string disconnected",
+ "Warning 221": "PV string current unbalanced",
+ "Warning 300": "No grid connection / grid power failure",
+ "Warning 301": "Grid voltage out of range",
+ "Warning 302": "Grid frequency out of range",
+ "Warning 303": "System overload",
+ "Warning 308": "Meter disconnected",
+ "Warning 309": "Meter L/N reversed",
+ "Warning 310": "N-PE voltage abnormal",
+ "Warning 311": "Phase sequence error (auto-adjusts)",
+ "Warning 400": "Fan failure",
+ "Warning 401": "Meter abnormal",
+ "Warning 402": "Optimizer communication abnormal",
+ "Warning 407": "Over-temperature",
+ "Warning 408": "NTC temperature sensor broken",
+ "Warning 411": "Sync signal abnormal",
+ "Warning 412": "Grid connection requirements not met",
+ "Warning 500": "Inverter-battery communication failed",
+ "Warning 501": "Battery disconnected",
+ "Warning 502": "Battery voltage too high",
+ "Warning 503": "Battery voltage too low",
+ "Warning 504": "Battery terminals reversed",
+ "Warning 505": "Lead-acid battery temp sensor disconnected",
+ "Warning 506": "Battery temperature out of range",
+ "Warning 507": "BMS fault: charging/discharging failed",
+ "Warning 508": "Lithium battery overload protection",
+ "Warning 509": "BMS communication abnormal",
+ "Warning 510": "BAT SPD function abnormal",
+ "Warning 600": "Output DC component bias abnormal",
+ "Warning 601": "High DC in output voltage",
+ "Warning 602": "Off-grid output voltage too low",
+ "Warning 603": "Off-grid output voltage too high",
+ "Warning 604": "Off-grid output overcurrent",
+ "Warning 605": "Off-grid bus voltage too low",
+ "Warning 606": "Off-grid output overload",
+ "Warning 609": "Balanced circuit abnormal"
};
const errorDescriptionMap: { [key: string]: string } = {
+ // BMS errors
"Tam": "Tam: Recoverable, BMS temperature too low",
"TaM2": "TaM2: Recoverable, BMS temperature too high",
"Tbm": "Tbm: Recoverable, Battery temperature too low",
@@ -153,12 +310,204 @@ function Log(props: LogProps) {
"HTFS": "HTFS: Recoverable, Unrecoverable: Heater Fuse Blown",
"DATA": "DATA: Recoverable, Unrecoverable: Parameters out of range",
"LMPA": "LMPA: Unrecoverable, String voltages unbalance alarm",
- "HEBT": "HEBT: Recoverable, oss of heartbeat"
+ "HEBT": "HEBT: Recoverable, oss of heartbeat",
+
+ // Sinexcel errors (ERROR severity - require manual intervention)
+ "Abnormal grid voltage": "Grid voltage abnormal",
+ "Abnormal grid frequency": "Grid frequency abnormal",
+ "Grid voltage phase loss": "Grid phase loss detected",
+ "Abnormal output voltage": "Output voltage abnormal",
+ "Abnormal output frequency": "Output frequency abnormal",
+ "Abnormalnullline": "Null/neutral line abnormal",
+ "Insulation fault": "Insulation fault detected",
+ "Leakage protection fault": "Leakage/ground fault protection tripped",
+ "Auxiliary power fault": "Auxiliary power supply fault",
+ "Fan fault": "Cooling fan fault",
+ "Model capacity fault": "Model/capacity configuration fault",
+ "Abnormal lightning arrester": "Surge protection device abnormal",
+ "Battery 1not connected": "Battery 1 not connected",
+ "Battery 2not connected": "Battery 2 not connected",
+ "AbnormalPV 1current sharing": "PV 1 current sharing abnormal",
+ "AbnormalPV 2current sharing": "PV 2 current sharing abnormal",
+ "DC bus voltage unbalance": "DC bus voltage unbalance",
+ "System output overload": "System output overloaded",
+ "Inverter overload": "Inverter overloaded",
+ "Inverter overload timeout": "Inverter overload timeout",
+ "Battery 1overload timeout": "Battery 1 overload timeout",
+ "Battery 2overload timeout": "Battery 2 overload timeout",
+ "DSP 1para meter setting fault": "DSP 1 parameter setting fault",
+ "DSP 2para meter setting fault": "DSP 2 parameter setting fault",
+ "DSPversion compatibility fault": "DSP version compatibility fault",
+ "CPLDversion compatibility fault": "CPLD version compatibility fault",
+ "CPLD communication fault": "CPLD communication fault",
+ "DSP communication fault": "DSP communication fault",
+ "Relayself-checkfails": "Relay self-check failed",
+ "Abnormal inverter": "Abnormal inverter condition",
+ "Balancedcircuit overload timeout": "Balance circuit overload timeout",
+ "PV 1overload timeout": "PV 1 overload timeout",
+ "PV 2overload timeout": "PV 2 overload timeout",
+ "Abnormaloff-grid output voltage": "Off-grid output voltage abnormal",
+ "Parallel communicationalarm": "Parallel communication alarm",
+ "Inverter relayopen": "Inverter relay open",
+ "PV 3not connected": "PV 3 not connected",
+ "PV 4not connected": "PV 4 not connected",
+ "PV 3overload timeout": "PV 3 overload timeout",
+ "PV 4overload timeout": "PV 4 overload timeout",
+ "Abnormal diesel generator voltage": "Diesel generator voltage abnormal",
+ "Abnormal diesel generator frequency": "Diesel generator frequency abnormal",
+ "Diesel generator voltageoutof phase": "Diesel generator out of phase",
+ "Lead battery temperature abnormality": "Lead battery temperature abnormal",
+ "Abnormal grid current": "Grid current abnormal",
+ "Generator overload": "Generator overloaded",
+ "Opencircuitof power grid relay": "Grid relay open circuit",
+ "Shortcircuitof power grid relay": "Grid relay short circuit",
+ "generator Relayopencircuit": "Generator relay open circuit",
+ "generator Relayshortcircuit": "Generator relay short circuit",
+ "Load power overload": "Load power overload",
+ "Abnormal leakage self-check": "Leakage self-check abnormal",
+
+ // Sinexcel PROTECTION errors (require service - do not restart)
+ "PV 1power tube fault": "PV 1 power tube fault - Contact Service",
+ "PV 2power tube fault": "PV 2 power tube fault - Contact Service",
+ "Battery 1power tube fault": "Battery 1 power tube fault - Contact Service",
+ "Battery 2power tube fault": "Battery 2 power tube fault - Contact Service",
+ "Inverter power tube fault": "Inverter power tube fault - Contact Service",
+ "Hardware bus over voltage": "Hardware bus overvoltage - Contact Service",
+ "Hardware over current": "Hardware overcurrent - Contact Service",
+ "DC converter hardware over voltage": "DC converter hardware overvoltage - Contact Service",
+ "DC converter hardware over current": "DC converter hardware overcurrent - Contact Service",
+ "Inverter relayshort circuit": "Inverter relay short circuit - Contact Service",
+ "Reverse meter connection": "Meter connected in reverse - Contact Service",
+ "PV 3power tube failure": "PV 3 power tube failure - Contact Service",
+ "PV 4power tube Failure": "PV 4 power tube failure - Contact Service",
+ "PV 3reverse connection": "PV 3 reverse connection - Contact Service",
+ "PV 4reverse connection": "PV 4 reverse connection - Contact Service",
+ "Diesel generator voltage reverse sequence": "Generator phase reversed - Contact Service",
+
+ // Growatt errors (PROTECTION severity)
+ "Error 309": "Grid ROCOF abnormal",
+ "Error 311": "Export limitation fail-safe",
+ "Error 400": "DCI bias abnormal",
+ "Error 402": "High DC in output current",
+ "Error 404": "Bus voltage sampling abnormal",
+ "Error 405": "Relay fault",
+ "Error 408": "Over-temperature protection",
+ "Error 409": "Bus voltage abnormal",
+ "Error 411": "Internal communication failure",
+ "Error 412": "Temperature sensor disconnected",
+ "Error 413": "IGBT drive fault",
+ "Error 414": "EEPROM error",
+ "Error 415": "Auxiliary power supply abnormal",
+ "Error 416": "DC/AC overcurrent protection",
+ "Error 417": "Communication protocol mismatch",
+ "Error 418": "DSP/COM firmware mismatch",
+ "Error 419": "DSP software/hardware mismatch",
+ "Error 421": "CPLD abnormal",
+ "Error 422": "Redundancy sampling inconsistent",
+ "Error 423": "PWM pass-through signal failure",
+ "Error 425": "AFCI self-test failure",
+ "Error 426": "PV current sampling abnormal",
+ "Error 427": "AC current sampling abnormal",
+ "Error 429": "BUS soft-boot failure",
+ "Error 430": "EPO fault",
+ "Error 431": "Monitoring chip BOOT verification failed",
+ "Error 500": "BMS-inverter communication failed",
+ "Error 501": "BMS: battery charge/discharge failed",
+ "Error 503": "Battery voltage exceeds threshold",
+ "Error 504": "Battery temperature out of range",
+ "Error 506": "Battery open-circuited",
+ "Error 507": "Battery overload protection",
+ "Error 508": "BUS2 voltage abnormal",
+ "Error 509": "BAT charge overcurrent protection",
+ "Error 510": "BAT discharge overcurrent protection",
+ "Error 511": "BAT soft start failed",
+ "Error 601": "Off-grid bus voltage low",
+ "Error 602": "Abnormal voltage at off-grid terminal",
+ "Error 603": "Off-grid soft start failed",
+ "Error 604": "Off-grid output voltage abnormal",
+ "Error 605": "Balanced circuit self-test failed",
+ "Error 606": "High DC in output voltage",
+ "Error 608": "Off-grid parallel signal abnormal",
+ "AFCI Fault": "Arc fault detected - Check PV connections",
+ "GFCI High": "High leakage current detected",
+ "PV Voltage High": "DC input voltage exceeds limit"
};
return (
+
+ {/* AI Diagnosis banner — shown when loading or a diagnosis is available */}
+ {(diagnosisLoading || diagnosis) && (
+
+
+
+
+ {/* loading state */}
+ {diagnosisLoading && (
+
+
+
+
+
+
+ )}
+
+ {/* diagnosis result */}
+ {diagnosis && !diagnosisLoading && (
+ <>
+
+
+
+
+
+ {diagnosedError}
+
+
+
+
+ {diagnosis.explanation}
+
+
+ setDiagnosisExpanded(!diagnosisExpanded)}
+ sx={{ textTransform: 'none', p: 0, mt: 1 }}
+ >
+
+
+
+ {diagnosisExpanded && (
+
+
+
+
+
+ {diagnosis.causes.map((cause, i) => (
+ {cause}
+ ))}
+
+
+
+
+
+
+ {diagnosis.nextSteps.map((step, i) => (
+ {step}
+ ))}
+
+
+ )}
+ >
+ )}
+
+
+
+ )}
+